OM-244 324 Page 8
SECTION 3
−
INSTALLATION
3-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974
−
1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
!
This equipment does not comply with IEC 61000
−
3
−
12. If it is connected to a public low voltage system, it is the responsibility of
the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equip-
ment may be connected.
ce-emc 2 2010-10
3-2. Serial Number And Rating Label Location
The serial number and rating information for the power source is located on the rear of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
3-3. IP Rating
IP Rating: 23. This equipment is designed for outdoor use. It may be stored, but is not intended to be used outside during precipitation unless sheltered.
Operating Temperature Range: 14
F (-10
C) to 104
F (40
C). Ratings were developed at an ambient temperature of 20
C to 25
C.
3-4. Specifications
Welding
Process
Rated Output
Welding
Amperage
Range
Max.
Open-Circuit
Voltage (U0)
Amperes Input At Rated
Output, 50/60Hz
KVA
KW
Dimensions
Weight
380
400
440
Stick
200 A @ 28
VDC,
40% Duty
Cycle
5
−
200
68 VDC
13.5
12.8
11.5
8.86
6.51
Length: 17-1/4 in.
(438 mm)
Width: 7-9/16 in.
(192 mm)
Height: 13-3/8 in.
(333 mm)
28 lb
(12.5 Kg)
TIG
200 A @ 18
VDC,
40% Duty
Cycle
8.7
8.3
7.5
5.73
4.2