Revision date: 120813
Page 25 of 46
Check the K1 pressure switch and K2-4 thermostat.
Connect air at 6-8 bar to the regulator turn, turn the knob on the regulator to increase pressure
setting while you measure between cable 46 and 66 on the K1 pressure switch with resistance
or summer measurement, at approx. 3.5 bar the K1 pressure switch should switch on.
Correct value is 0 ohm.
If the pressure switch doesn’t switch on replace the pressure switch.
Measure between pin 1-2 on the A3 and A4 connector on the E4 secondary PCB with
resistance or summer measurement.
Correct value is 0 ohm.
If value is high or no connection is measured then replace thermostat K2-4.
Summary of Contents for UPC 1041
Page 1: ...Revision date 120813 Page 1 of 46 Instruction manual UPC 1041 Air Plasma Cutter...
Page 38: ...Revision date 120813 Page 38 of 46...
Page 39: ...Revision date 120813 Page 39 of 46...
Page 40: ...Revision date 120813 Page 40 of 46...
Page 41: ...Revision date 120813 Page 41 of 46...
Page 42: ...Revision date 120813 Page 42 of 46...
Page 43: ...Revision date 120813 Page 43 of 46 Notes...
Page 44: ...Revision date 120813 Page 44 of 46 Notes...