Measure between
pin 1-2
and
7-8
with the meter set to
diode test
and the
positive probe
on
the
red lead
.
Correct value is approx. 1.15. This value may differ a bit between different instruments but if
very low or a short is measured on one pair then replace the E1 primary PCB.
Measure between pin
1-2
and
7-8
with the meter set to diode test and the
negative probe
on
the
red lead
.
Correct value is approx. 1.10, this value may differ a bit between different instruments but if
very low or a short is measured on one pair then replace the E1 primary PCB.