Revision date: 120813
Page 20 of 46
Measure between
cable
no.
73
and the
Out (+)
on the
E1 primary pcb
with the meter set to
diode test
and
negative probe
on
cable 73
. Correct value is approx. 0.35. This value may
differ a bit between different instruments but if very low or a short is measured then replace
the E1 primary PCB.
Reconnect cable 73 and 74 to the D5 main rectifier.