Measured values
Version: 2022 / V2
Page: 48
BAMOCAR-PG-D3-700-100/160
6
Measured values
6.1
DC link DC BUS voltage, battery voltage (700 V)
BAMOCAR
DC circuit voltage Parameter 0xEB DC-BUS %
Maximum voltage
800 V
25200
154
Overvoltage switch off
780 V
24570
150
Without power voltage
0 V
0
Standaridzation
1 V
31,50
0,194
Tolerance: +/-2 %
DC-BUS Battery voltage
Measuring tol/-2 %
Example for settings on the BAMOCAR
DC-BUS max. (0xA5
H
)
for limit voltage
Num 0x0B
Bemerkung
144 %
750 V=
23625
1 % corresponds 5,2 V
135 %
700 V=
22050
DC-BUS min. (0xA5
L
)
for undervoltage
116 %
600 V=
18900
58 %
300 V=
9450
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
11000
12000
13000
14000
15000
16000
17000
18000
19000
20000
21000
22000
23000
24000
25000
26000
27000
28000
29000
30000
31000
32000
33000
0
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100