Electrical installation
Version: 2022 / V2
Page: 30
BAMOCAR-PG-D3-700-100/160
3.7
Power connections
PG cable gland
metal M25 x 1.5 with shield contact
Connection - Motor U
Connection - Motor V
Connection - Motor W
Connection - Battery pos. pole
Connection- Battery neg. pole
Connecting cables max. 25 mm²
Assembly
:
Only shielded cables to be used!
Connection example
:
Adapt the dimensions to the cables and cable glands used!
Strip outer insulation to 34-38 mm, shorten shield to 10 mm,
Strip inner insulation, copper strand to 7-12 mm,
cable lug insulation 22 mm (braided sleeve
or heat-shrink tubing).
Cable lug for M6 screw.
Slip complete PG gland including shield spring onto
cable,
slip the cable lug insulation onto cable
crimp cable strands into the cable lugs (15 mm)
Screw the PG gland into the unit.
Connect the cable lug to the internal conductor rail
and tighten the cap of the PG gland. Tighten the
gland of the cable lug.
Connection screw
: M6 x 8 (self-locking or corrugated washer, no toothed washer)
max. tightening torque 7 Nm
Note: The cable gland is not included in the delivery scope.