Electrical installation
Version: 2022 / V2
Page: 26
BAMOCAR-PG-D3-700-100/160
3.4
EMV
Note: 12 V variant only on request
The devices adhere to the EU guidelines 2004/108/EC and the technical standard EN 61800-3 provided
that the following conditions are observed.
Mounting:
Unit is conductively mounted on a blank mounting plate 500 x 500 x 5 mm.
Mounting plate connected to earth via 10 mm².
Motor housing connected to earth via 10 mm².
Power shields connected to mounting plate.
X1:1 (PE2) connected to X6 via 1.5 mm².
X6 (housing ground) connected to mounting plate via 4 mm² cable.
Battery cables and motor cables shielded.
Control connections:
Signal lines shielded, analogue signal lines twisted and shielded.
Shield: short contact on ground bolt X6.
Battery connection:
12..700
V dc voltage