Page 32
WELD SENTRY 2
weld counts from SPC Program History. Enter a Schedule number to display the summary screen.
Press [ENTER] to print the Reject Report. Press
◄
/
►
to display Reject Reports for any other Programs A-E.
Note: The SPC weld count is different than the system Weld Counters or Weld Count on the Run screen.
Those counters increment whenever any weld is monitored for any Schedule. The SPC weld count includes
only the welds counted in SPC History for an individual program. When collecting data, it may be helpful
to both reset the system weld counters and erase SPC history to coordinate the system and program counts.
TOTAL WELDS:
Total number of welds saved in Program History.
Total
Welds
=
100%.
ACCEPT COUNT: Number of welds which are inside the programmed Upper and Lower Limits.
% = Accept Count
÷
Total Welds
REJECT HIGH:
Number of welds which were higher than the programmed Upper Limit.
% = Reject High
÷
Total Welds
REJECT LOW:
Number of welds which were lower higher than the programmed Upper Limit.
% = Reject Low
÷
Total Welds