background image

,QVWDOODWLRQ

Before operation the unit, you must read this user’s Manual thoroughly and 
retain it for future reference.   

Before cleaning the unit, you must remove it from the wall or bracket. 
You must clean it with a wet cloth.    Never use liquid cleanser. 

Enough space must be ensured to installation of this P/T and never rotate
PAN/TILT housing forcibly without driving by remote controller. 

Be careful not to put this unit on an unstable stand, tripod, shelf, or Table. 

Do not leave the unit in a location near heat sources or humidifier.

Be careful of electric overload on the electric terminal or extension cable, 
otherwise there can be risk of permanent damage.

You must stop operation this unit and never connect the connector of the 

cable to the unit in case of the following situations. 

z

In case of the control cable being damaged. 

z

When any liquid or unfavorable material falls into the unit. 

z

When the unit doesn’t work properly according to the instruction. 

z

When the unit fell down or the P/T was damaged. 

You must make an expert examine the accessories whether they have the 
same specific character when you need replacement of them.

Summary of Contents for EV3000-PT-EXIR

Page 1: ...d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d V V V V V V V V V V V V V V V V V V V V V V V V...

Page 2: ...Specifications 3 Installation 4 Operation 5 Dimensional diagram 6 Communications Protocol Part B FLIR IR Cameras Part C Conduit Sealing Instructions for Equipment in Hazardous Locations SSHQGL I IR c...

Page 3: ...I Divisions I and II Groups A B C and D Class II Divisions I and II Groups E F G T5 Class I Zone 1 AEx d IIC Ex d IIC T5 The electro polished Aluminumstainless steel construction makes the EV3000 PT...

Page 4: ...II Groups E F G T5 Class I Zone 1 AEx d IIC Ex d IIC T5 0DWHULDOV Aluminum Stainless Steel 5RWDWLQJ DQJOH 3DQ a 7LOW a 5RWDWLQJ VSHHG Pan 0 1 12 sec Tilt 0 1 6 sec Motor PRWRU Temperature WR Preset 0...

Page 5: ...t leave the unit in a location near heat sources or humidifier Be careful of electric overload on the electric terminal or extension cable otherwise there can be risk of permanent damage You must stop...

Page 6: ...3000 PT within 20 ft and the DC24V should be supplied using AWG16 wires 3 1 2 The built in receiver address is set to 1 and Baud rate is set to 2400 bps the unit controlled using any Pelco D keyboard...

Page 7: ...it systems WARNING Failure to follow safety instructions may cause ignition of hazardous atmosphere resulting in serious personal injury and or property damage EXPLOSIONPROOF SWITCH IGNITABLE GASES OR...

Page 8: ...ures Figure 2 Seals Within Conduit Smaller Than 2 Inches If the conduit is 2 inches or larger a seal must be placed within 18 inches of the enclosure Figure 3 Seals Within Conduit Larger Than 2 Inches...