GENERAL

Construction Aluminum / Sainless steel

Finish Electro polish

Viewing Ge Window for cooled and uncooled

Designed and manufactured to meet the

UL/cUL Hazardous Locations Listed per NEC Division and Zone     

requirement

Class I, Divisions I and II, Groups A, B, C, and D

Class II, Divisions I and II, Groups E, F, G, T5

Class I, Zone 1, AEx d IIC, Ex d IIC, T5

   

ś

0DWHULDOV

Aluminum / Stainless Steel

ś

5RWDWLQJDQJOH

3DQƒa

7LOWƒ aƒ

ƒ

ś

5RWDWLQJVSHHG

Pan :0.1

~ 12

/sec, Tilt :0.1

~ 6

/sec

ٻ

Motor

%/'&PRWRU

Temperature

Ȕ WRȔ

Preset 

000~127(128 Presets)

Interface

RS-485

Receiver address

000~255(256 Addresses)

Default address is “1” at factory.

Baud rate

2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS

(Default : 2400bps) 

Protocol

PELCO-D(8 Data,1 stop,No parity)

. IR Windows

Quadra band IR optic

Power consumption

200Watt

Input Power
Requirements

DC 24V / 10Amp







Summary of Contents for EV3000-PT-EXIR

Page 1: ...d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d d V V V V V V V V V V V V V V V V V V V V V V V V...

Page 2: ...Specifications 3 Installation 4 Operation 5 Dimensional diagram 6 Communications Protocol Part B FLIR IR Cameras Part C Conduit Sealing Instructions for Equipment in Hazardous Locations SSHQGL I IR c...

Page 3: ...I Divisions I and II Groups A B C and D Class II Divisions I and II Groups E F G T5 Class I Zone 1 AEx d IIC Ex d IIC T5 The electro polished Aluminumstainless steel construction makes the EV3000 PT...

Page 4: ...II Groups E F G T5 Class I Zone 1 AEx d IIC Ex d IIC T5 0DWHULDOV Aluminum Stainless Steel 5RWDWLQJ DQJOH 3DQ a 7LOW a 5RWDWLQJ VSHHG Pan 0 1 12 sec Tilt 0 1 6 sec Motor PRWRU Temperature WR Preset 0...

Page 5: ...t leave the unit in a location near heat sources or humidifier Be careful of electric overload on the electric terminal or extension cable otherwise there can be risk of permanent damage You must stop...

Page 6: ...3000 PT within 20 ft and the DC24V should be supplied using AWG16 wires 3 1 2 The built in receiver address is set to 1 and Baud rate is set to 2400 bps the unit controlled using any Pelco D keyboard...

Page 7: ...it systems WARNING Failure to follow safety instructions may cause ignition of hazardous atmosphere resulting in serious personal injury and or property damage EXPLOSIONPROOF SWITCH IGNITABLE GASES OR...

Page 8: ...ures Figure 2 Seals Within Conduit Smaller Than 2 Inches If the conduit is 2 inches or larger a seal must be placed within 18 inches of the enclosure Figure 3 Seals Within Conduit Larger Than 2 Inches...

Page 9: ...kes a dam that keeps the sealing compound in the chamber of the sealing fitting while it cures and hardens The fiber dam is also used to separate the individual conductors so the sealing compound seal...

Page 10: ...fications are subject to change Check website www unitedvisionsolutions com Contact us For repair service or if problem s still exist after troubleshooting Call Customer Service 1 413 592 8477 tech un...

Reviews: