Keypad programming flowchart 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default values marked with 

*

 

 
 

Entering Menu is always done with B(3 s) + 000000 if the Master Code is not changed. 
 

Submenu 1

 - Change Master Code. The Master Code must be 6 digits. After enrolling new 

Master Code the ACL875W automatically exits the Menu and the new master code must be typed 
to enter the menu. 
 

Submenu 2

 - Select Type of Wiegand. The Wiegand selected must be the same as the 

controller’s Wiegand Input where the ACL805SUW-RDMF Keypad is being connected. Example: 
If you use a controller that recognizes Wiegand 34 bit, then enter the menu of ACL805SUW-
RDMF, press 2, then press 3. 
 

Submenu 3

 - Select Output Protocol. Keypad have the following outputs: 

3-1

 Single Wiegand - Keypad will send code in wiegand format 

3-3

 Clock & Data - Keypad will send the code in Clock & Data format 

3-5

 8 bit per key - Each key press will be sent as 8 bit data immediately. Key press will be sent as following table: 

 

 

 

3-6

 6 bit 

per key - 

Each key press will be sent as 6 bit data immediately. 

3-7

 4 bit per key - Each key press will be sent as 4 bit data immediately. 

 
Submenu 4

 - PIN C

ode Length. If “0” is selected, then any PIN Code with any length can be sent, 

but the PIN Code is typed with “A” for confirmation (ex. 123 + A). If 1 to 8 is selected the PIN Code 
length is set by the number selected. 
 
 

 

Key 

Wiegand output 

240 

225 

210 

195 

180 

165 

150 

135 

120 

105 

90 

75 

*

 

*

 

*

 