Quick Start Guide 

 

 

 

 

 

 

 

 

 

Summary of Contents for V30 Plus

Page 1: ...4 01 33 Lexington Drive Bella Vista NSW 2153 Australia 1800 015 458 International 61 2 9960 7200 Quick Start Guide ...

Page 2: ...4 01 33 Lexington Drive Bella Vista NSW 2153 Australia 1800 015 458 International 61 2 9960 7200 ...

Page 3: ...1 Accessing the V30 WEB interface ________________________________________12 V30 Web interface ___________________________________________________ 12 Accessing the V30 Web interface________________________________________ 12 Finger Scanner Maintenance ___________________________________________13 Cleaning ____________________________________________________________ 13 Users failing verifications _...

Page 4: ... Examples The following images show where the finger is placed correctly onto the sensor glass The bottom flat part of the finger is covering the whole of the sensor glass while the finger is pressed firmly onto the glass surface Finger placed correctly on the sensor glass Slight pressure is necessary Finger placed correctly on the sensor glass Slight pressure is necessary This part of the finger ...

Page 5: ...Quick Start Guide V2 016_2 V30 Plus Docx 29 07 2019 Page 5 of 19 The following images show various incorrect positioning s of the finger onto the sensor glass The final images shows correct placement ...

Page 6: ...y 1 1 2 or 3 Fingers 7 Select the authority level for scanner access scroll through the options by pressing NO OUT To select desired level press YES IN AUTH USER ACCEPT Y N 8 Scroll through the finger options by pressing NO OUT until desired finger choice is displayed on screen RIGHT INDEX ACCEPT Y N 9 Once finger selected for use press YES IN Scanner glass window will flash a RED strobe PLEASE PL...

Page 7: ...sonal ID Number SYSTEM ACCESS ENTER ID NO 3 Place your finger for verification PLEASE PLACE FINGER FINGER NAME Verification status displays DAY DATE TIME VERIFIED 4 Press No Out key for the Menu Yes To Enroll ALT For Menu 5 Please place the required finger Please place 1st Finger 6 Remove finger as instructed Remove Finger 7 The resultant score is now displayed Minutiae 25 8 You can now Enroll or ...

Page 8: ...Press Alt key for the Menu Yes To Enroll ALT For Menu 5 Press 1 key for Template 1 Template 2 Database 3 Setup 4 MGR 6 Use number pad to select number the ID of the person to be deleted ENTER ID ALT 7 Press YES IN on prompt Finger 1 Accept ID No XXXX FINGER1 Accept 8 Press 4 key To Delete 1 AUTH 2 T Zone 3 SEC 4 DELETE 9 The user will now be deleted DELETED If the user has more than one finger enr...

Page 9: ...Green light DAY DATE TIME VERIFIED 4 Press Alt key for the Menu Yes To Enroll ALT For Menu 5 Press 1 key for Template 1 Template 2 Setup 3 MGR 6 Use number pad to select number the ID of the person to be modified ENTER ID ALT 7 Press YES IN on prompt Finger 1 Accept ID No XXXX FINGER1 Accept 8 Press 1 key for AUTH 1 AUTH 2 T Zone 3 SEC 4 DELETE 9 Press NO OUT to change YES IN to accept AUTH USER A...

Page 10: ...5 Press 1 key For Template 1 Template 2 Setup 3 MGR 6 Use number pad to select number the ID of the person to be modified ENTER ID ALT 7 Press YES IN on prompt Finger 1 Accept ID No XXXX FINGER1 Accept 8 Press 3 key For SEC 1 AUTH 2 T Zone 3 SEC 4 DELETE 9 Press 1 key For THOLD 1 THOLD 2 PASSWD 10 Press YES IN to change THRESHOLD 20 CHANGE YES NO 11 Use number pad to enter the new threshold settin...

Page 11: ...late 1 2 or 3 Fingers 7 The displays confirms that the next steps are to create a password Creating Passwd Template Only 8 Select the authority level for scanner access scroll through the options by pressing NO OUT To select desired level press YES IN AUTH USER ACCEPT Y N 9 The scanner now initializes the password script Creat New Passwd 10 Enter a minimum of 4 numbers for the users password Compl...

Page 12: ... to that of a V90 Accessing the V30 Web interface To access a particular V30 s Web Interface on your network the IP address of the unit must be known The V30 Web interface can be accessed by many different devices that have network connectivity Including WiFi to the Finger Scanner s network Enter the IP address of your V30 in a WEB browser on your PC Laptop Tablet Smart Phone Depending on the Firm...

Page 13: ...WEB interface Finger Scanner Maintenance Cleaning The scanner normally does not require any maintenance but occasionally the sensor will need a clean as a build up of foreign matter can accumulate on the sensor glass and surrounding areas To clean wipe the glass and surrounding areas with a damp clean lint free towel or cloth Important When cleaning glass only use clean materials which are free of...

Page 14: ... are difficult to capture A medical skin condition e g Dermatitis The sensor window requires cleaning Steps to overcome Verification failures The following steps should be conducted to overcome verification failures Firstly conduct a finger scan test as detailed previously this will give a score Users with a reading below 16 should be re enrolled Finger Test Conduct a finger scan test to verify th...

Page 15: ...laced over the entire glass section of the Finger Scanner The sensor will automatically detect the placement of the finger Successful verification is indicated with a Green light Un Successful verification is indicated with a RED light The sensor light is illuminated once the finger placement is detected On a successful scan the transaction to the FingerLan software is recorded as a Verify_OK ...

Page 16: ...nger Scanner Step 1 To Clock In press the Yes In To Clock Out Press the No Out Step 2 Type in ID PIN or employee number on the keypad Step 3 Place your finger on the sensor plate NOTE The device will prompt you which finger to scan via the screen User steps Step 1 Clock In or Out Step 2 Enter ID or Pin Step 3 Place finger ...

Page 17: ...een LED 8 If unsuccessful the V30 Plus will request you to PLEASE TRY AGAIN Two further failures will result in the V30 Plus displaying the word UNSUCCESSFUL as well as light up the red LED Handy Hints 1 Ensure that you type in your employee number correctly 2 Always read the screen on the device It displays the information required at each step 3 Place finger correctly on the scanning pad 4 If yo...

Page 18: ...Quick Start Guide V2 016_2 V30 Plus Docx 29 07 2019 Page 18 of 19 Notes ...