background image

User Guide

For EVO Systems

We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit 

www.paradox.com and send us your comments.

EVO641 / EVO641R

DGP2-641BL / DGP2-641RB

DGP2-648BL

Summary of Contents for DGP2-641BL

Page 1: ...VO Systems We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments EVO641 EVO641R DGP2 641BL DGP2 6...

Page 2: ......

Page 3: ...w Access Control Works 16 Trouble Display 17 Trouble Display 17 Event Record Display 18 Additional Features 19 Programmable Outputs PGMs 19 Keypad Settings 19 Modifying illumination settings on the DG...

Page 4: ......

Page 5: ...s and menus to guide you through the system s operations Your installer can even customize the messages on LCD keypads for your home or business The LED display of the DGP2 648BL LED will let you asse...

Page 6: ...eypad will display the status of all its assigned areas ACTION Lights Access Stay Force Byp Mem Trbl and Prg Lights will illuminate according to the status of the system Numerical Lights Zones ON Zone...

Page 7: ...the system reverts to a previous status or when an operation is incorrectly entered the keypad emits a continuous beep tone BEEEEEEEEEEP 2 2 Confidential Mode Your installer can program keypads to not...

Page 8: ...ss ENTER when the area you want to view appears on the screen 3 Press CLEAR to exit In Area Status Display mode the following information will scroll on the LCD screen ready if all zones in the select...

Page 9: ...u have access to more than one area select the area s you wish to Stay arm refer to section 3 1 on page 4 4 4 Instant Arming This feature is the same as Stay arming except that there is no Entry Delay...

Page 10: ...all reinstates the zones that were bypassed the last time your system was armed To activate Bypass Recall 1 Enter your ACCESS CODE 2 Press the BYP button 3 Press the MEM button Zones bypassed the last...

Page 11: ...he ACC button when the area you want to program appears on the screen 5 Enter the time you want the area to be armed according to the 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 6 Press the EN...

Page 12: ...ACCESS CODE 2 In the case of a false alarm call your monitoring station quickly to advise them of the false alarm In the case of a burglar alarm leave the premises and call the Police from a safe loc...

Page 13: ...other options are manually changed the System Master Code will immediately revert to its original programming You can assign a label name to a user access code at any point during the Programming Use...

Page 14: ...e Pressing the FORCE key will delete the character or blank space found at the current cursor position ARM Delete Until the End Pressing the ARM key will delete all characters and spaces to the right...

Page 15: ...o program user access codes If you wish to program user access codes using the NEware Software please contact your installer for information If the keypad emits a rejection beep at any point during th...

Page 16: ...nd if PGMs are programmed by your installer the user can only control the PGMs Refer to section 9 1 on page 19 for a more detailed explanation of PGMs User Options see section 6 7 on page User Labels...

Page 17: ...s Option 6 Stay Instant Arm When option 6 is ON the Stay and Instant arm features are enabled The user can now Stay or Instant arm their assigned areas Option 7 Force Arm When option 7 is ON the Force...

Page 18: ...ature extends a user s scheduled access period through an Access Control door by the amount programmed by your installer For example if the user s assigned schedule for the door is Monday to Friday fr...

Page 19: ...ming and Disarming with Card 7 2 1 Arming with Card presented to a door during its assigned Schedule refer to step 8 in section 6 5 1 on page 12 presented to a door within its assigned Access Level re...

Page 20: ...e EVO641R DGP2 641RB keypad on Door 02 on Tuesday August 3 at 3 00 p m she will gain access to the room Figure 4 Example B If Bonnie presents her card to the reader or the EVO641R DGP2 641RB keypad on...

Page 21: ...m serviced 8 1 1 Group 1 System 1 AC Failure The control panel has detected a power failure This means that your system is running on the backup battery If this trouble occurs when your establishment...

Page 22: ...cess Granted You will only be able to view the events that occurred in the area s assigned to your user access code Only available on LCD keypads To view the Event Record 1 Enter your ACCESS CODE 2 Pr...

Page 23: ...E Your keypad will emit a Confirmation Beep The ACCESS action light will flash 2 Press the 6 key Your keypad will emit a Confirmation Beep the Prg action light will illuminate and the numerical light...

Page 24: ...s will stop beeping when opened HH MM 4 Press CLEAR to exit chime programming 9 6 Panic Alarms Your system can be programmed to send an alarm to your monitoring station to request help from the polic...

Page 25: ...set by your installer 4 When the VDMP3 answers the line you are prompted to enter your access code 5 Options are given to arm disarm 1 and control features PGMs 2 Not connected to an answering machine...

Page 26: ...22 User Guide...

Page 27: ...use your system requires no maintenance other than regular testing We recommend that your installer change the battery every three years 11 4 System Test Speak to your installer before conducting a S...

Page 28: ...ke detector 3 If the problem remains after 90 seconds the alarm will sound again Press CLEAR again 4 The system will delay reporting the alert for another 30 seconds If you are unable to cancel the fa...

Page 29: ...ires 12 5 Home Fire Warning System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire install smok...

Page 30: ...ramming the user labels of a Hebrew LCD keypad Instead of using Table 2 on page 10 and Table 3 on page 11 use Tables 9 and 10 below Refer to section 6 3 on page 9 for information on programming user l...

Page 31: ...amming the user labels of a Russian LCD keypad Instead of using Table 2 on page 10 and Table 3 on page 11 use Tables 11 and 12 below Refer to section 6 3 on page 9 for information on programming user...

Page 32: ...15 s 131 147 163 179 195 211 227 e 243 y 020 036 052 4 068 D 084 T 100 d 116 t 132 148 164 180 196 212 G 228 z 244 w 021 037 053 5 069 E 085 U 101 e 117 u 133 149 165 181 197 213 229 h 245 q 022 038 0...

Page 33: ...Touch 6 Quick Function 20 Bypass Bypass Recall 6 Programming 5 C Card Access Control Arming with 15 Disarming with 15 Characters Special 11 Chime Zones 20 Clock Set Time and Date 19 Code Follows Sched...

Page 34: ...cters 11 Special Characters Greek 28 Special Characters Hebrew 26 Special Characters Russian 27 Special Function Keys 10 Standard Fire Zone 24 Stay Arming 5 System Master Code 9 System Test 23 T Tampe...

Page 35: ...ions of Alarm Systems It must be understood that while your Paradox alarm system is highly advanced and secure it does not offer any guaranteed protection against burglary fire or other emergency fire...

Page 36: ...rt in Canada or the U S call 1 800 791 1919 Monday to Friday from 8 00 a m to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 0...

Reviews: