17
INSTALLING
YOUR
ROOM
HEATER
‐
continued
FREESTANDING
INTERIOR
VERTICAL
INSTALLATION
1.
Locate
your
Pellet
Stove
Room
Heater
in
a
location
which
meets
the
requirements
of
this
manual,
but
in
an
area
where
it
does
not
interfere
with
the
house
framing,
wiring,
etc.
2.
Install
a
non
‐
combustible
hearth
pad
underneath
the
pellet
stove.
This
pad
should
extend
at
least
6”
(152mm)
in
front
of
the
unit.
3.
Place
your
Pellet
Stove
Room
Heater
on
the
hearth
pad
and
locate
the
unit
in
manner
that
will
leave
the
exhaust
vent
with
a
minimum
of
3”
(75mm)
clearance
to
any
combustible
wall.
4.
When
installing
the
air
intake,
locate
the
center
of
the
combustion
air
intake
pipe
at
the
back
of
your
unit.
Line
up
the
center
with
the
same
spot
on
your
exterior
wall
and
cut
a
2
‐
1/2”
(64mm)
diameter
hole
through
the
wall.
5.
Secure
all
vent
joint
connections
with
3
screws.
Seal
the
exhaust
vent
joint
connections
with
high
temperature
silicone
sealant.
6.
Install
the
combustion
air
intake
pipe.
7.
Install
a
tee,
with
a
cleanout,
on
the
exhaust
pipe
found
at
the
rear
of
your
unit.
8.
Install
approved
vent
upward
through
the
ceiling.
When
you
pass
through
the
combustible
framing
ensure
that
the
appropriate
ceiling
firestop
is
used.
You
must
maintain
a
minimum
3”
(75mm)
clearance
to
combustibles
and
keep
any
insulation
away
from
the
exhaust
vent.
9.
Extend
the
exhaust
vent
through
the
roof
flashing
and
ensure
that
the
vertical
cap
is
approximately
36”
(900mm)
above
the
roof.