5
SAFETY
INFORMATION
‐
continued
Keep
foreign
objects
out
of
the
hopper.
Contact
your
local
building
officials
to
obtain
a
permit
and
information
on
any
installation
restrictions
or
inspection
requirements
in
your
area.
Be
sure
to
notify
your
insurance
company
of
your
new
U.S.
Stove
Pellet
Burning
Room
Heater.
Allow
the
Pellet
Stove
Room
Heater
to
cool
before
performing
any
maintenance.
Ashes
must
be
disposed
of
in
a
metal
container
with
a
tight
lid
and
placed
on
a
noncombustible
surface
well
away
from
your
home.
Check
the
venting
system,
at
least
twice
a
year,
for
creosote
build
‐
up.
Keep
all
door/lid
seals
and
gaskets
in
good
condition.
Adequate
ventilation
air
is
required
to
operate
this
heater.
During
operation
the
heater
draws
air
for
combustion
which
can
be
assisted
by
the
installation
of
outside
combustion
air
inlets.
However,
certain
weather
conditions
such
as
icing
or
use
of
kitchen
exhaust
fans
may
impact
and
reduce
the
effectiveness
of
vents.
It
is
important
to
note
that
room
air
starvation
well
negatively
impact
the
operation
of
the
heater.
If
power
outages
with
battery
backup
or
room
air
starvation
occurs
during
operation
of
heater,
smoke
in
the
house
may
result.
This
may
trigger
smoke
detectors
if
they
are
installed.
CAUTION:
DO
NOT
CONNECT
TO
ANY
AIR
DISTRIBUTION
DUCT
OR
SYSTEM.
DO
NOT
USE
CHEMICALS
OR
FLUIDS
TO
START
THE
FIRE.
NEVER
USE
GASOLINE,
GASOLINE
TYPE
LANTERN
FUEL,
KEROSENE,
CHARCOAL
LIGHTER
FLUID,
OR
SIMILAR
LIQUIDS
TO
START
OR
FRESHEN
UP
A
FIRE
IN
THE
HEATER.
KEEP
ALL
SUCH
LIQUIDS
WELL
AWAY
FROM
THE
HEATER
WHILE
IT
IS
IN
USE.
USING
THESE
CHEMICALS
COULD
CAUSE
BODILY
HARM,
HEATER
DAMAGE
AND
WILL
VOID
THE
WARRANTY.
DO
NOT
BURN
GARBAGE
OR
FLAMMABLE
FLUIDS
SUCH
AS
GASOLINE,
NAPHTHA
OR
ENGINE
OIL.
HOT
WHILE
IN
OPERATION.
KEEP
CHILDREN,
CLOTHING
AND
FURNITURE
AWAY
FROM
THE
HEATER.
CONTACT
MAY
CAUSE
SKIN
BURNS.
YOUNG
CHILDREN
SHOULD
BE
SUPERVISED
WHEN
THEY
ARE
IN
THE
SAME
ROOM
AS
THE
STOVE.
DO
NOT
ATTEMPT
TO
OPERATE
THE
VENT
TUBE
CLEANER
WHILE
THE
PELLET
STOVE
IS
IN
OPERATION
OR
COOLING
DOWN;
WAIT
UNTIL
PELLET
STOVE
HAS
COOLED
COMPLETELY
BEFORE
PERFORMING
THIS
PROCEDURE.
ENSURE
THAT
PEOPLE
ARE
AWARE
THAT
THE
VENT
TUBE
CLEANER
KNOB
WILL
BE
VERY
HOT
DURING
PELLET
STOVE
OPERATION
AND
CAN
BE
A
BURN
HAZARD.
OTHER
RADIANT
SURFACES
OF
THE
STOVE
WILL
BE
HOT
DURING
OPERATION
AND
CAN
BE
A
BURN
HAZARD.