background image

© 2021 U

nited S

tat

es Sto

ve C

ompany

13

INSTR

UCTIONS D

’UTILISATION INS

TALL

ATION

AVER

TISSEMENT

:

• 

N'UTILISEZ PAS DE PR

ODUIT

S CHIMIQUE

S OU 

DE FLUIDE

S PO

UR ALLUMER LE FEU - N'UTILISEZ 

JAMAIS D'E

SSENCE, DE C

OMBU

STIBLE P

OUR 

LANTERNE DE TYPE E

SSENCE, DE KÉR

OSÈNE, DE 

LIQUIDE À BRIQ

UET À CHARBON O

U DE LIQUIDE

SIMILAIRE

S PO

UR ALLUMER O

U «RAFR

AÎCHIR» UN 

FEU DANS CE P

OÊLE. GARDEZ TO

US CE

S LIQUIDE

ÉLOIGNÉ

S DU P

OÊLE PENDANT S

ON UTILISATION.

• 

CHAUD EN F

ONCTIONNEMENT

. TENIR LES ENF

ANTS, 

LES VÊTEMENT

S ET LES MEUBLE

S À L'ÉCAR

T. LE 

CONT

ACT PEUT C

AU

SER DES BR

ÛLURE

S DE LA 

PEAU.

Cet appar

eil est c

onçu pour br

ûler uniquement PFI pelle

ts 

Premium qualit

é. NE P

AS BR

ÛLER:

1. 

Des déchets;

2. 

Coupur

es de gaz

on ou les déchets de jar

din;

3. 

Les ma

téria

ux con

tenan

t du caout

chouc, y compris les 

pneumatiques;

4. 

Les ma

téria

ux con

tenan

t de plastique;

5. 

Produit

s pétr

oliers des déche

ts, des pein

tur

es ou des 

diluants de pein

tur

e ou de produit

s d’asphalt

e;

6. 

Les ma

téria

ux con

tenan

t de l’amian

te;

7. 

Les débris de c

onstr

uction ou de démolition;

8. 

Liens ou de bois trait

é sous pr

ession R

ailroad;

9. 

Fumier ou r

estes d’

animaux;

10. 

Sel de bois flott

é de l’ea

u ou d’autr

es matéria

ux 

préalablemen

t eau s

alée sat

urés;

11. 

Bois de; ou

12. 

Les pr

oduits de papier

, de car

ton, de c

ontr

eplaqué ou de 

partic

ules. L’in

ter

diction de la c

ombustion de c

es matéria

ux 

n’in

ter

dit pas l’

utilisation des démarr

eurs de f

eu fabriqués 

à partir de papier

, de car

ton, de s

ciure, de cir

e et s

ubst

ances 

similaires 

dans le 

but de 

déclencher un 

incendie 

dans un 

poêle à bois affec

té.

Brûler c

es matéria

ux peut entr

aîner la libération de f

umées 

toxiques 

ou de 

rendr

e l’appar

eil de 

chauff

age 

de la 

fumée 

ineffic

ace e

t caus

e.

CARB

URANT APPR

OPRIÉ

AVER

TISSEMENT

:

L’APP

AREIL EST C

ONÇU P

OUR ÊTRE UTILISÉ A

VEC 

DU C

OMBU

STIBLE EN GR

ANULÉS C

ONFORME À 

OU EX

CÉDANT L

A NORME ÉTABLIE P

AR LE PELLET 

FUEL INSTITUTE (PFI). L

’UTILISATION D

’AUTRE

COMB

USTIBLE

S ANNULE LA GAR

ANTIE.

Votr

e poêle à granulés es

t conç

u pour brûler des gr

anulés de bois 

dur de qualité s

upérieure c

onformes à la norme PFI (P

ellet F

uels 

Instit

ute) 

(densit

é minimale 

de 40 

lb par 

pied cube

, diamè

tre 

de 

1/4 à 5

/16 moins de 8 2

00 BTU / lb

, humidité in

férieur

e à 8% 

en poids, cendr

es inférieur

e à 1% en poids et s

el inférieur à 3

00 

parties 

par million

). Les gr

anulés mous, 

con

tenan

t une quan

tité 

exc

essiv

e de sciur

e de bois en vrac, qui on

t été ou s

ont mouillés, 

réduir

ont les per

formanc

es. Rang

ez v

os pelle

ts dans un endr

oit 

sec. NE s

tock

ez P

AS le c

arburan

t dans les déga

gemen

ts 

d’ins

talla

tion de l’appar

eil ou dans l’espac

e requis pour f

aire le 

plein et enle

ver les c

endres. C

ela pourrait pr

ovoquer un inc

endie. 

Ne pas tr

op brûler ou utilis

er des combus

tibles vola

tiles ou 

des combus

tibles, cela pourr

ait caus

er des dommages a

ux 

personnes e

t à la proprié

té. C

et appar

eil n’es

t homologué que 

pour brûler du c

arburan

t sous f

orme de granulés de bois ! L

es 

granulés appr

ouvés mes

uren

t 1/4 po

. Ou 5

/16 po

. De diamètr

et pa

s plus de 1 po

. De long. L

es granulés plus long

s ou plus épais 

peuven

t bloquer les ailett

es de la tarièr

e, c

e qui empêche une 

bonne alimenta

tion en granulés. Il es

t inter

dit de brûler du bois 

sous d’

autr

es formes que des gr

anulés. Il s’agir

ait d’une viola

tion 

des codes du bâ

timent pour les

quels le poêle a été appr

ouvé, 

et c

ela annulerait t

outes les g

aran

ties. La 

conc

eption du poêle 

intè

gre l’

alimenta

tion aut

omatique des gr

anulés dans le feu 

selon un r

ythme s

oigneusemen

t calc

ulé. U

n autr

e combus

tible 

intr

oduit à la main n’a

ugmenter

ait pas la pr

oduction de chaleur

mais pourr

ait nuir

e gr

avemen

t aux 

performanc

es du 

poêle 

en génér

ant 

beauc

oup de 

fumée

. Ne 

brûle

z pa

s de 

granulés 

mouillés. Les per

formanc

es du poêle dépendent f

ortemen

de la qualité des gr

anulés. Évit

ez les mar

ques de granulés qui 

prés

enten

t les car

actéris

tiques suiv

antes :

• U

n exc

ès de fines – Le t

erme « fines » décrit les gr

anulés 

écras

és ou les matéria

ux libres qui r

essemblen

t à de la sciur

ou à du sable

. Il est po

ssible de t

amiser les gr

anulés avan

t de 

les placer dans la tr

émie pour éliminer la plupart des fines.

• Des lian

ts – C

ertains gr

anulés son

t produit

s avec des 

matéria

ux liants qui les a

gglutinen

t, les « lien

t ».

• U

n con

tenu éle

vé en c

endres – C

es granulés de ma

uvais

qualité cr

éent s

ouven

t de la fumée e

t salis

sen

t la vitre. 

L’en

tretien de

vra ê

tre plus fr

équent. Il f

audr

a vider le 

pot de c

ombustion e

t aspir

er la tot

alité du s

yst

ème plus 

fréquemmen

t. Des 

granulés 

de ma

uvais

e qualit

é pourraien

endommager 

la tarièr

e. Nous 

ne pouv

ons ac

cep

ter 

auc

une 

respons

abilité 

en ca

s de 

dommages 

dus à 

des gr

anulés de 

mauv

aise qualit

é.

AVER

TISSEMENT

:

• 

GARDER LE

S OBJET

S ÉTRANGER

S HORS DE L

TRÉMIE.

• 

LES PIÈ

CES MOBILE

S DE CE POÊLE S

ONT MUES P

AR 

DES MO

TEURS ÉLE

CTRIQ

UES A

U CO

UPLE ÉLEVÉ. 

ÉLOIGNEZ T

OUTE

S LES P

ARTIE

S DU C

ORPS DE L

TARIÈRE L

ORSQ

UE LE POÊLE E

ST BR

ANCHÉ SUR L

PRISE ÉLECTRIQ

UE. CES PIÈ

CES MOBILE

S PEUVENT 

COMMENCER 

À BO

UGER 

À TO

UT MOMENT LOR

SQ

UE 

LE POÊLE E

ST BR

ANCHÉ.

Summary of Contents for KP60-XH

Page 1: ...ng or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use...

Page 2: ...2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions burning Douglas Fir dimensional lumber this heater has b...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO N...

Page 5: ...or non combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor pr...

Page 6: ...ate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certifi...

Page 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Page 8: ...d void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house...

Page 9: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Page 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Page 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Page 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Page 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Page 14: ...ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down...

Page 15: ...NTERIOR CHAMBERS Burn Pot Periodically remove and clean the burn pot and the area inside the burn pot housing In particular it is advisable to clean out the holes in the burn pot to remove any build u...

Page 16: ...f chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repair...

Page 17: ...f glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperat...

Page 18: ...ets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearofobstructions Auger sys...

Page 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Page 20: ...t W Adhesive 7 28 ft 2 893159 Clear Glass 1 3 88324 1 Rope Gasket 5 17 ft 4 80780 IR Remote 1 5 69762 Burnpot Assembly 1 6 80491 Microswitch 1 7 80518 Keypad Assembly 1 8 80549 Pressure Switch 1 9 883...

Page 21: ...ll help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification lab...

Page 22: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 23: ...2021 United States Stove Company 23 NOTES...

Page 24: ...24 2021 United States Stove Company NOTES...

Page 25: ...2021 United States Stove Company 25 NOTES...

Page 26: ..._____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie _____________________...

Page 27: ...reil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le n...

Page 28: ...sif 7 28 pi 2 893159 Verre propre 1 3 88324 Joint de corde 1 po 5 17 pi 4 80780 T l commande IR 1 5 69762 Assemblage du pot de combustion 1 6 80491 Micro interrupteur 1 7 80518 Assemblage du clavier 1...

Page 29: ...t deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleu...

Page 30: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Page 31: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Page 32: ...verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre...

Page 33: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Page 34: ...ent le pot de combustion et la zone l int rieur du bo tier du pot de combustion En particulier il est conseill de nettoyer les trous du pot de combustion pour liminer toute accumulation qui pourrait e...

Page 35: ...S CIRCONSTANCES ET UN PROBL ME DE S CURIT PEUT PROVOQUER DES TINCELLES OU DES FUM ES ENTRANT DANS LA PI CE LA PORTE DOIT TRE FERM E ET SCELL E PENDANT LE FONCTIONNEMENT Si la porte est ouverte pendant...

Page 36: ...sont mouill s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le ple...

Page 37: ...faire en sorte que le po le se programme entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po l...

Page 38: ...itesse conform ment au r glage du niveau de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Dr...

Page 39: ...ant une dur e suffisante le pot de combustion se remplira avec trop de combustible et le feu s touffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Page 40: ...L installation travers le mur est l installation la moins ch re et la plus simple Ne jamais mettre fin l vent de fin sous un pont dans une alc ve sous une fen tre ou entre deux fen tres 90 Elbow Cap d...

Page 41: ...ure 4 Localisez le centre du tuyau d chappement de votre unit Ce point devrait ensuite tre tendu la paroi int rieure de votre maison Une fois que vous avez localis le point central sur la paroi int ri...

Page 42: ...coude ou t r duit le potentiel de tirage de 30 50 Tous les joints du syst me de ventilation doivent tre fix s par au moins 3 vis et tous les joints doivent tre scell s avec du mastic silicone Hi Temp...

Page 43: ...obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air ext rieur et votre revendeur pour l achat V rifiez aupr s de vos responsables locaux du b timent car d aut...

Page 44: ...des cendres La protection du plancher doit s tendre sous et 2 51 mm de chaque c t du t de chemin e pour une installation verticale int rieure Les installations canadiennes n cessitent un minimum de 1...

Page 45: ...UPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTE...

Page 46: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 47: ...e tarif r glage le plus bas 1 5 lbs hr Taille de Pellet peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utilise...

Page 48: ...ictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre no...

Reviews: