INSTALLATION
SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - DO NOT INSTALL IN A SLEEPING ROOM
CAUTION! - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.
In addition to the previously detailed installation requirements, mobile home installations must meet the following
requirements:
•
The stove must be permanently attached to the floor.
•
The stove must have a permanent outside air source (USSC Part No FAK1780 Fresh Air Kit is recommended).
•
The stove must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a
serrated or star washer to penetrate paint or protective coating to ensure grounding.
•
Vent must be 3 or 4-inch “PL” Vent and must extend a minimum or 36-inches above the roofline of the mobile
home and must be installed using a UL/ULC listed ceiling fire stop and rain cap.
•
When moving your mobile home, all exterior venting must be removed while the mobile home is being relo-
cated. After relocation, all venting must be reinstalled and securely fastened.
•
Check with your local building officials as other codes may apply.