background image

-6-

© 2021 United States Stove Company

INSTALLATION

OUTSIDE AIR SUPPLY 

(OPTIONAL, UNLESS INSTALLING IN A 

MOBILE HOME)

Depending on your location and home construction, 

outside air may be necessary for optimal performance. 

Your stove is approved to be installed with an outside air 

intake (69FAK) which is necessary for a mobile home. 

You can purchase the 69FAK through your heater dealer. 

Installation instructions are supplied with the air intake 

kit.

ATTENTION:

DO NOT VENT UNDER ANY PORCH, DECK, 

AWNING, OR IN ANY SEMI ENCLOSED OR 

ROOFED AREA. DOING SO MAY RESULT IN 

UNPREDICTABLE AIRFLOW AT THE VENT CAP 

UNDER CERTAIN CONDITIONS AND CAN AFFECT 

THE PERFORMANCE OF YOUR STOVE, AS WELL 

AS, OTHER UNFORESEEABLE ISSUES.

SECURING APPLIANCE TO THE FLOOR

Use the designated holes to secure the unit to the floor.

Fresh Air 

Intake

Exhaust 

Pipe

WARNING! DO NOT INSTALL IN SLEEPING ROOM.

CAUTION! THE STRUCTURAL INTEGRITY OF THE 

MOBILE HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED.

WHEN INSTALLED IN A MOBILE HOME, THE STOVE 

MUST BE GROUNDED DIRECTLY TO THE STEEL 

CHASSIS AND BOLTED TO THE FLOOR.

In addition to the previously detailed installation 

requirements, mobile home installations must meet 

the following requirements:

•  This stove must be securely fastened to the floor of 

the mobile home using two 1/4” lag bolts that are long 

enough to go through both a hearth pad, if used, and 

the floor of the home. 

•  The heater must be electrically grounded to the steel 

chassis of the mobile home with 8 GA copper wire 

using a serrated or star washer to penetrate paint or 

protective coating to ensure grounding.

•  Vent must be 3 or 4-inch “PL” Vent and must extend 

a minimum or 36” (914 mm) above the roof line of the 

mobile home and must be installed using a certified 

ceiling fire stop and rain cap.

•  When moving your mobile home, all exterior venting 

must be removed while the mobile home is being 

relocated. After relocation, all venting must be 

reinstalled and securely fastened.

•  Outside Air is mandatory for mobile home installation. 

See Outside Air Supply section and your dealer for 

purchasing.

•  Check with your local building officials as other codes 

may apply.

VENTING REQUIREMENTS

WARNING:

•  INSTALL VENT AT CLEARANCES SPECIFIED BY 

THE VENT MANUFACTURER.

•  DO NOT CONNECT THE PELLET VENT TO A VENT 

SERVING ANY OTHER APPLIANCE OR STOVE.

•  DO NOT INSTALL A FLUE DAMPER IN THE 

EXHAUST VENTING SYSTEM OF THIS UNIT.

The following installation guidelines must be followed 

to ensure conformity with both the safety listing of this 

stove and to local building codes. Do not use makeshift 

methods or compromise in the installation.

IMPORTANT:

THIS UNIT IS EQUIPPED WITH A NEGATIVE DRAFT 

SYSTEM THAT PULLS AIR THROUGH THE BURN 

POT AND PUSHES THE EXHAUST OUT OF THE 

DWELLING. IF THIS UNIT IS CONNECTED TO A FLUE 

SYSTEM OTHER THAN THE WAY EXPLAINED IN 

THIS MANUAL, IT WILL NOT FUNCTION PROPERLY.

MAXIMUM VENTING DISTANCE

Installation MUST include at least 3-feet of vertical pipe 

outside the home. This will create some natural draft to 

reduce the possibility of smoke or odor during appliance 

shutdown and keep exhaust from causing a nuisance or 

hazard by exposing people or shrubs to high temperatures. 

The maximum recommend vertical venting height is 12-

feet for 3-inch type “PL” vent. Total length of horizontal 

Summary of Contents for King

Page 1: ...d this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warran...

Page 2: ...s burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 277...

Page 3: ...________________________________ If no Date of inspection of existing venting system _________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as...

Page 4: ...TER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BU...

Page 5: ...lation Canadian installations require 18 450 mm in front of the unit B B D C A B B C Dimensions in mm A Rear through wall 1 25 B Side 6 152 C Front 6 152 D Rear interior vertical 2 50 Canada installat...

Page 6: ...sher to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed u...

Page 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Page 8: ...d your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house fram...

Page 9: ...nowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installati...

Page 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Page 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Page 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Page 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Page 14: ...e stove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 A...

Page 15: ...switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and c...

Page 16: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Page 17: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Page 18: ...nd or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearo...

Page 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Page 20: ...20 2021 United States Stove Company REPAIR PARTS 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Page 21: ...30 69763 Exhaust Duct Weldment 1 31 88117 Exhaust Duct Gasket 1 32 80473 Exhaust Blower 1 33 88100 Exhaust Blower Gasket 1 34 80480 Thermistor 1 35 86633 Ignitor Tube Weldment 1 36 80619 Ignitor Cartr...

Page 22: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Page 23: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 24: ...24 2021 United States Stove Company NOTES...

Page 25: ...20...

Page 26: ...gement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1 22 891132 Bague 1 23 83534 Retaining Ring 1 24 69719 Auger Cover 1 25 891161 Bottom Plate Retenue 1 26 25495 Moteur d entra nement Br...

Page 27: ...18 Sch ma des pi ces 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Page 28: ...17 Sch ma de c blage CORRECT FAUX Assurez vous que les ls sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Page 29: ...deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur...

Page 30: ...ire V ri ez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans n est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combus...

Page 31: ...lev es VITRE NETTOYAGE RETRAIT ET REMPLACEMENT DE LA VITRE CASS E DE LA PORTE Nettoyage Nous recommandons l utilisation d un nettoyant pour vitres de bonne qualit Si une accumulation de cr osote ou d...

Page 32: ...r un po le chaud N utilisez jamais le po le avec une vitre cass e une fuite de gaz de combustion pourrait se produire AVERTISSEMENT LE et la chemin e connecteur doit tre maintenu en bon tat et propre...

Page 33: ...permanents au r chauffeur PREMIER FEU R glez la gamme de chaleur et la vitesse du ventilateur sur un r glage de 3 et laissez le po le fonctionner de cette mani re pendant environ trois 3 heures ou plu...

Page 34: ...e voyant DEL ON Marche est allum Si l interrupteur de la tr mie est ouvert couvercle ouvert le voyant DEL Heat Range du degr de chaleur s allumera Si le couvercle est ferm le voyant DEL Heat Range du...

Page 35: ...pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mod...

Page 36: ...9 Raccordement Du Thermostat...

Page 37: ...mporte quelle qualit de combustible br le ef cacement en respectant les proc dures d taill es dans le reste de ce manuel Comme une pression de tirage forc e est n cessaire au processus de combustion l...

Page 38: ...rts appropri es du plafond et le chaperon de toiture fournis par le fabricant de tuyaux respectez les indications du fabricant de tuyaux Il est important de remarquer que si votre section verticale de...

Page 39: ...pable de vous fournir un kit qui g rera la grande partie de cette installation celui ci devra comprendre un manchon mural qui permettra d obtenir le d gagement correct travers le mur combustible Une f...

Page 40: ...ines ou nuisibles TYPE DE TIRAGE D AIR POUR GRANUL S Un syst me d vacuation de type PL de 3 ou 4 pouces list UL doit tre utilis pour l installation et connect au raccord de conduite fourni au dos du p...

Page 41: ...e doit tre suf samment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaq...

Page 42: ...ll s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enle...

Page 43: ...e Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une surface non combustible o...

Page 44: ...s exigences d inspection et d terminer si vous avez besoin d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agen...

Reviews: