background image

-21-

© 2021 United States Stove Company

REPAIR PARTS

Key

Part #

Description

Qty

1

69524

Feed Door Assembly

1

2

891372

Door Hinge Pad

2

3

25080B Feed Door Latch

1

4

69693

Burnpot Housing Weldment

1

5

86624

Burnpot Assembly

1

6

25513

Ash Cleanout

2

7

69713MB Top/Lid Weldment

1

8

891148

Plastic Handle

1

9

69515MB Cabinet Side - Left

1

10

80778

PCB - Printed Circuit Board

1

11

25488MB Cabinet Side - Right

1

12

69787

Hopper Assembly

1

13

80491

Microswitch

1

14

83541

#4-40 Bolt

2

15

893039

Remote Sensor Bracket

1

16

25480MB Access Panel

1

17

80461

Power Supply Cord

1

18

80462

Receptacle, 3 Prong

1

19

891164

Auger Housing Weldment

1

20

891141

Auger

1

21

891189

Top Bushing Plate

1

22

891132

Bushing

1

23

83534

Retaining Ring

1

24

69719

Auger Cover

1

25

891161

Bottom Plate Retainer

1

26

25495

Drive Motor Bracket

1

27

891169

Heater Hose

2

28

80488

Auger Motor

1

29

83529

Hair Pin

1

30

69763

Exhaust Duct Weldment

1

31

88117

Exhaust Duct Gasket

1

32

80473

Exhaust Blower

1

33

88100

Exhaust Blower Gasket

1

34

80480

Thermistor

1

35

86633

Ignitor Tube Weldment

1

36

80619

Ignitor Cartridge

1

37

88118

Ignitor Flange Gasket

1

38

80472

Distribution Blower

1

39

88106

Distribution Blower Gasket

1

40

25774

Pressure Switch Bracket

1

41

80549

Pressure Switch

1

42

89586

Nipple

1

43

891121

Silicone Hose

3”

44

83537

Hose Clamp (#4)

1

45

88119

Insulation Blanket

1

46

88168

Burnpot Housing Gasket

1

47

26096MB Hearth

1

48

26097MB Grill Mount - Left

1

49

26098MB Grill Mount - Right

1

50

69791MB Louver/Grill Assembly

1

Key

Part #

Description

Qty

1

891135

Spring Handle

1

2

25492

Handle, Door

1

3

83506

3/8 x 1-1/4 Roll Pin

1

4

25507

Feed Door

1

5

88066

5/8” Rope Gasket

4.5 ft

6

891053

Door Glass

1

7

25521

Top Glass Retainer

1

8

25520

Bottom Glass Retainer

1

9

25393

Glass Retainer

1

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL KING PARTS PURCHASED 

THROUGH YOUR DEALER OR DIRECTLY FROM KING. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.

Summary of Contents for King

Page 1: ...d this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warran...

Page 2: ...s burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 277...

Page 3: ...________________________________ If no Date of inspection of existing venting system _________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as...

Page 4: ...TER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BU...

Page 5: ...lation Canadian installations require 18 450 mm in front of the unit B B D C A B B C Dimensions in mm A Rear through wall 1 25 B Side 6 152 C Front 6 152 D Rear interior vertical 2 50 Canada installat...

Page 6: ...sher to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed u...

Page 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Page 8: ...d your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house fram...

Page 9: ...nowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installati...

Page 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Page 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Page 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Page 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Page 14: ...e stove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 A...

Page 15: ...switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and c...

Page 16: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Page 17: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Page 18: ...nd or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearo...

Page 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Page 20: ...20 2021 United States Stove Company REPAIR PARTS 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Page 21: ...30 69763 Exhaust Duct Weldment 1 31 88117 Exhaust Duct Gasket 1 32 80473 Exhaust Blower 1 33 88100 Exhaust Blower Gasket 1 34 80480 Thermistor 1 35 86633 Ignitor Tube Weldment 1 36 80619 Ignitor Cartr...

Page 22: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Page 23: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 24: ...24 2021 United States Stove Company NOTES...

Page 25: ...20...

Page 26: ...gement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1 22 891132 Bague 1 23 83534 Retaining Ring 1 24 69719 Auger Cover 1 25 891161 Bottom Plate Retenue 1 26 25495 Moteur d entra nement Br...

Page 27: ...18 Sch ma des pi ces 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Page 28: ...17 Sch ma de c blage CORRECT FAUX Assurez vous que les ls sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Page 29: ...deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur...

Page 30: ...ire V ri ez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans n est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combus...

Page 31: ...lev es VITRE NETTOYAGE RETRAIT ET REMPLACEMENT DE LA VITRE CASS E DE LA PORTE Nettoyage Nous recommandons l utilisation d un nettoyant pour vitres de bonne qualit Si une accumulation de cr osote ou d...

Page 32: ...r un po le chaud N utilisez jamais le po le avec une vitre cass e une fuite de gaz de combustion pourrait se produire AVERTISSEMENT LE et la chemin e connecteur doit tre maintenu en bon tat et propre...

Page 33: ...permanents au r chauffeur PREMIER FEU R glez la gamme de chaleur et la vitesse du ventilateur sur un r glage de 3 et laissez le po le fonctionner de cette mani re pendant environ trois 3 heures ou plu...

Page 34: ...e voyant DEL ON Marche est allum Si l interrupteur de la tr mie est ouvert couvercle ouvert le voyant DEL Heat Range du degr de chaleur s allumera Si le couvercle est ferm le voyant DEL Heat Range du...

Page 35: ...pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mod...

Page 36: ...9 Raccordement Du Thermostat...

Page 37: ...mporte quelle qualit de combustible br le ef cacement en respectant les proc dures d taill es dans le reste de ce manuel Comme une pression de tirage forc e est n cessaire au processus de combustion l...

Page 38: ...rts appropri es du plafond et le chaperon de toiture fournis par le fabricant de tuyaux respectez les indications du fabricant de tuyaux Il est important de remarquer que si votre section verticale de...

Page 39: ...pable de vous fournir un kit qui g rera la grande partie de cette installation celui ci devra comprendre un manchon mural qui permettra d obtenir le d gagement correct travers le mur combustible Une f...

Page 40: ...ines ou nuisibles TYPE DE TIRAGE D AIR POUR GRANUL S Un syst me d vacuation de type PL de 3 ou 4 pouces list UL doit tre utilis pour l installation et connect au raccord de conduite fourni au dos du p...

Page 41: ...e doit tre suf samment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaq...

Page 42: ...ll s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enle...

Page 43: ...e Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une surface non combustible o...

Page 44: ...s exigences d inspection et d terminer si vous avez besoin d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agen...

Reviews: