UT-102

UNIVERSAL PROCESS INDICATOR & CONTROLLER

6

*
*
*

Default Password will be 

0000

              Protected Parameter Password will be 

1111

NOTE  : 

These are the whole parameter list. Parameters
can be very as per Type 

or

 Requirement by User.

         

*

              To come out from Programming Mode to 
              Normal mode Press        key in any step.

WARNING

INJURY

Programming parameter should be accessed only by Personnel who are 
technically competent to do so. Local regulations regarding electrical & 
safety must be observed.

FAILURE TO COMPLY WITH THESE INSTRUCTION COULD BE RESULT IN SERIOUS INJURY OR DEATH

PV

SV

3.2       Mode Access Flow Chart.

8888

8888

Normal Mode

Mode Selection

Configuration

Setup

Mode

Mode

Change  

Password Mode

Calibration

Mode

Pass

w

or

d Pr

ot

ect

ed

Pass

w

or

d Pr

ot

ect

ed

Pass

w

or

d Pr

ot

ect

ed

*

Any New Password

*

BAUD

9600

PR1T

NoNE

CTYP

LEAN

oFfS

0038

GAIN
0007

COnf

0000

1NP

Pt-1

TSP1

L oN

TSP2

L oN

DP

0001

DEAD

no

TSP3

L oN

TSP4

L oN

SETP

0000

ZERO

000.0

SPAN

100.0

SP1

030.0

HYS1

000.2

SP2

050.0

HYS2

000.2

SP3

060.0

HYS3

000.2

SP4

080.0

HYS4

000.2

oFST

000.0

oP-L

000.0

oP-H

100.0

CAL

0000

CALZ

CALS

CALL

CALH

CALA

CPAS

oPAS
0000

nPAS
8888

0000

Press      +       key to enter into 
the Programming mode from
Normal mode

NADD

0001

MODE

MODE

MODE

MODE

pass

pass

pass

pass

D-sp

sp-1

Summary of Contents for UT-102

Page 1: ...6 www utplindia in www Model No UT 102 UNIVERSAL PROCESS INDICATOR CONTROLLER INSTRUCTION MANUAL M 96 x 96 Flame Proof UT 102 M COM www utplindia in RL 2 RL 1 RL 4 RL 3 102 0 102 0 UT 102 M COM www ut...

Page 2: ...ts Applying 240V AC to a controller rated for 12 24VDC will severely damage the controller and is a fire and smoke hazard This controller is suitable for connection to 230 15 VAC 50 Hz or 12 24 VDC po...

Page 3: ...GRAMMING 3 1 OPERATION INTERFACE 3 2 MODE ACCESS FLOW CHART 4 1 CONFIGURATION MODE 4 OPERATIONAL MODES 4 2 SETUP MODE 4 3 CALIBRATION MODE 4 4 CHANGE PASSWORD MODE 4 5 ERROR MESSAGE 5 COMMUNICATION MO...

Page 4: ...ange in the mode Two different configuration levels provide easy access to parameters A4 digit security code perverts una uthorized changes Parameters can also be hidden to user to prevent improper co...

Page 5: ...ale ANALOG V I SPECIAL ON DEMAND 0 1 of Full Scale Automatic Software based self compensation Cold Junction Comp OPEN or OVER indication on display Sensor Break Info AS per Input Range Table Range Lim...

Page 6: ...5 26 D NC NO C RELAY 4 RS 485 D NC NO C RELAY 3 NC RELAY 2 NO C NC NO C RELAY 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B B OUTPUT Analog Out TPS 24VDC v SUPPLY E P UT 102 15 16 17 18 N T C mA Noise Filter...

Page 7: ...a status of parameter Press to change set points in normal view UP KEY UP Key allows increasing the value of a digit selected or changing the status of parameter in programming mode Press to change se...

Page 8: ...OMPLY WITH THESE INSTRUCTION COULD BE RESULT IN SERIOUS INJURY OR DEATH PV SV 3 2 Mode Access Flow Chart 8888 8888 Normal Mode Mode Selection Configuration Setup Mode Mode Change Password Mode Calibra...

Page 9: ...nge the type Up by key Down by key Range Input Type is as follows TC 4 spCL pt 1 1 5v 0 20 4 20 2 5v 10v CU53 Default Value 0000 tsp1 L on ALARM 1 RELAY ACTION Alarm Relay activation direction Values...

Page 10: ...for Analog Linear input only oFfS 0038 OFFSET FOR INPUT FACTORY SET VALUE Offset Parameter for corresponding Input Value Factory Set for every Input Default Value 0038 As per Input NOTE Factory set va...

Page 11: ...se by key Range Values between 199 9 to 999 9 Default Value 000 2 Hys1 000 2 HYSTERESIS ALARM 1 Value Diff between On and Off of Relay 1 Scroll the digit by key Increase by key Range Values between 19...

Page 12: ...values range Range Default Value According to Input Type Note After Cali random value should be below 1000 appeared in display Range Default Value strt to start cal According to Output Type CALH strt...

Page 13: ...ontroller Controller circuit failed Check the power connection Check the supply voltage 4 4 Change Password Mode 4 5 Error Message Range Values Parameter PAsS 0000 CHANGE PASSWORD MODE PASSWORD Passwo...

Page 14: ...us protocol are as follows 5 4 MODBUS system schematic DATA READ ONLY SR NO 1 PROCESS VALUE PV PARAMETER ABSOLUTE ADDRESS ACCESS TYPE 40001 READ WRITE 3 SET POINT 1 SP1 40003 READ ONLY 2 DECIMAL POINT...

Page 15: ......

Reviews: