background image

30

Copyright 2009 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.

10. Under the 

WeeklySchedule

 tab, select 

Weekly Security Schedule

.

11. Double-click on a desired table cell (for example, 

row 1 

/

 column Thursday

). The Period Code 

window appears.

12. Click a desired time period (for example, 

00002359

) to set for 24 hours in this weekday. Click 

OK

.

Summary of Contents for Tashi

Page 1: ...A Versatile Multi Function Terminal User Manual Talk Mic 400664G Version 3 0...

Page 2: ......

Page 3: ...rotection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructi...

Page 4: ...claration of Conformity with Regard to the R TTE 1999 5 EC and EMC 89 336 EEC direc tives RoHS Statement This device conforms to RoHS Restriction of Hazardous Substances European Union regulations tha...

Page 5: ...ing Date and Time 4 Utilizing Software 4 Chapter 2 Using the Hardware 5 Using the Keypad 5 Using Proximity Reader 6 Using Fingerprint Reader 8 Using DECT Phone Optional 11 Chapter 3 Onscreen Setting 1...

Page 6: ...iv Appendix B Worldwide Support 46...

Page 7: ...time and atten dance management solutions on the market Features Powerful System 72 Mhz ARM7TDMI S System Memory 8 MB Flash ROM Display COG FSTN LCD with White Backlight 128 x 64 Pixel Resolution User...

Page 8: ...t behind the sensor on the back panel 2 Disable the antitheft function in the MT180 firmware See Advanced Setting on page 15 3 Open the case and short circuit pin2 and pin3 of the J5 connector NOTE Wh...

Page 9: ...g 1 Connect MT180 and a computer to the network 2 MT180 s default IP address is 192 168 2 127 Set the computer on the same subnet with MT180 For example IP Address 192 168 2 100 Network Mask 255 255 2...

Page 10: ...ge of applications in the TASHI network Learn about the main differences between MTTool and JanitorLite through the following Please contact a Unitech representative to acquire MTTool For more details...

Page 11: ...rompt to input 2 digit group number and a 4 digit group access password to open the door In Access Attendance Mode press F2 or F3 to switch into Attendance Mode Press F2 or F3 to choose the work shift...

Page 12: ...e Proximity Reader MT180 beeps three times The screen displays Invalid Card with the card number 5 In MTTool under the SysSet2 tab in the Card Setting box input the card number user name group number...

Page 13: ...he card type is compatible with the reader 6 Follow MT180 s onscreen instructions to enter the Card Info Query See General Settings on page 12 Swipe the card over the Proximity Reader MT180 beeps thre...

Page 14: ...ll or no finger Remove and place the finger on the fingerprint reader three times 5 Press F3 to enroll another fingerprint when the screen displays Collect finger OK Continue Press F5 to stop 6 After...

Page 15: ...JanitorLite to collect fingerprints through the following 1 Connect MT180 to a computer network See Establishing Terminal PC Connection on page 3 2 Enable Unitech MT Service in the Control Panel 3 On...

Page 16: ...s Co Ltd 5 Click User o User Management Double click DEMOUSER The User setting window appears Click FingerPrint The FingerPrint window appears 6 To collect fingerprint data from MT180 click Read The v...

Page 17: ...ss Talk Doorbell MT180 connects to the DECT phone while the screen displays Con nect Please wait The LED indicator on the DECT phone flashes and the phone rings with the MT180 s HS number HS1 by defau...

Page 18: ...the fingerprint reader Each card allows to enroll a maximum of three fingerprints Enter the ModifyCardPIN option Follow the onscreen prompt to swipe a card The screen displays Input old PIN Using the...

Page 19: ...the SetLanguage option to switch the terminal language Current supported languages are Eng lish Simplified Chinese and Traditional Chinese Enter the SetBacklight option to set the backlight behavior S...

Page 20: ...eboot option Select Yes to reboot the system The screen displays Device reboot Please wait and the system reboots itself Select No to go back to the Advanced options Enter the ResumeDefault option Sel...

Page 21: ...ce Utilize MTTool to manage time and attendance through the following 1 Set MT180 to a computer on the same subnet network 2 Execute MTTool on the computer 3 In MTTool and under the SysSet1 tab select...

Page 22: ...stered trademark of Unitech Electronics Co Ltd 4 In the Time box click Adjust to synchronize the system time with the computer 5 Click Get to double check MT180 s date and time settings 6 In the Termi...

Page 23: ...he Shift Setting box check a desired work shift for example On Morning Click Set 8 In the Card Setting field input the card number user name user number group number and etc Click Add a Card No NOTE S...

Page 24: ...cs Co Ltd 9 Under the WeeklySchedule tab in the Weekly Schedule Setting box select Weekly Atten dance Schedule 10 Double click a time code cell for example On morning shift duty The Period Code window...

Page 25: ...or this work shift in other weekdays The period code 7F displays on the shift row Click Set 13 In the GroupSet tab select the desired group for example 0 14 Double click on a desired table cell for ex...

Page 26: ...the table cell 16 In the Attendance Mode Setting box select None 17 Click Set Group Info on the top center of the screen Utilize JanitorLite to manage time and attendance through the following 1 Set M...

Page 27: ...192 168 110 230 in the IPHost field Click Apply 9 Click Reset to reset data in this controller A window appears asking to reset Click Yes MT180 screen displays messages Please wait EraseFingerInfo Pl...

Page 28: ...p name for example DEMO Click Apply and then OK to return to the User Group Setting window 14 Right click the desired group for example DEMO and click Append o Entity to add a new user The User settin...

Page 29: ...card number 18 Click OK to return to the User Group Setting window 19 Click Permit P o Permit Management 20 Select the desired user group for example DEMO and click Setting on the toolbar The Selected...

Page 30: ...desired work shift for example On Morning 24 Under the Shift Info tab select a desired weekday from the drop down menu for example Thursday 25 Double click inside the PeriodID field The Selected perio...

Page 31: ...Swipe Card to Clock In Swipe a card on the Proximity Reader while the standby screen on MT180 displays the desired work shift name for example morning shift work The user name for example TAttendance...

Page 32: ...the user controller and date and click OK The attendance record displays under the Preview tab Security Operation To prevent unauthorized access MT180 can setup a secure area which is enclosed by the...

Page 33: ...place or lift security bans by the same proximity card used for access control or time attendance mode Utilize MTTool to optimize security settings through the following 1 Connect Pin 4 CHECK to Pin...

Page 34: ...nics Co Ltd 5 In MTTool under the SysSet1 tab select WinSocket and input the IP address for example 192 168 110 230 Click Connect NOTE See Advanced Settings on page 13 to set MT180 s IP address 6 Clic...

Page 35: ...9 8 In the Set1 tab select Buzzer from the System Alarm Notification drop down menu Click Set 9 Under the SysSet2 tab in the Card Setting box input the card number user name user num ber group number...

Page 36: ...k of Unitech Electronics Co Ltd 10 Under the WeeklySchedule tab select Weekly Security Schedule 11 Double click on a desired table cell for example row 1 column Thursday The Period Code window appears...

Page 37: ...d Setting 31 13 The period code 7F displays on the table cell Click Set 14 Under the GroupSet tab select the desired group 0 15 Double click on a desired table cell row 1 column Thursday The Period Co...

Page 38: ...d time period for example 00002359 to set for 24 hours in this weekday Click OK The period code 7F displays on the table cell 17 In the Security Mode Control box select Enable Disable Security Mode 18...

Page 39: ...andby screen indicating a security ban Scenario II Lift Security Ban Press to enter the security setting screen while in standby status and SecuredStatus displays onscreen The current security status...

Page 40: ...ity ban is lifted SecuredAlarm disappears on the standby screen Check the loop and reconnect Pin 5 SAFE to Pin 10 GND Anti Pass Back Setting Enforce Anti Pass Back to control the entrance exit behavio...

Page 41: ...ect WinSocket and input the IP address for example 192 168 110 230 Click Connect NOTE See Advanced Settings on page 13 to set MT180 s IP address 5 Click Adjust to synchronize the system time with the...

Page 42: ...egistered trademark of Unitech Electronics Co Ltd 7 In the Terminal Setting box select Internal External from the Reader drop down menu Click Set 8 Under the SysSet2 tab in the Card Setting box input...

Page 43: ...e desired group 0 10 Double click on a desired table cell row 1 column Thursday The Period Code window appears 11 Click a desired time period for example 00002359 to set for 24 hours of access in this...

Page 44: ...e card reentry and re exit through the same door 1 Connect a secondary reader to MT180 via Drive RS232 NOTE While MT180 serves as an internal reader the secondary reader is the external reader Ensure...

Page 45: ...e ControllerName field enter the controller name for example MT180 9 In the IPHost field input the controller s IP address 192 168 110 230 Click Apply 10 Click Reset to reset data in this controller A...

Page 46: ...The UserGroup Setting window appears 14 In the GroupName field enter the user group name Demo Click Apply o OK to return to the JanitorLite Users Management window 15 Right click the desired group Dem...

Page 47: ...OK to return to the JanitorLite Users Management window 20 Click Permit P o Permit Management 21 Select the desired user group Demo and click Setting on the toolbar The Selected Control lers window ap...

Page 48: ...d to immediately send this command to the controller A window appears with the message Setting Successfully 25 Under the Entrance guard weekly plan tab select a desired weekday from the drop down menu...

Page 49: ...dis plays on the standby screen indicating that re exiting is not allowed Scenario II Re Entering Swipe the card on the internal reader Entrance with the user name APB displays on the standby screen S...

Page 50: ...gain on the external reader Re Exiting with the user name APB displays on the standby screen indicating that re exiting occured If utilizing JanitorLite Click Report R o Access Report Under the Con di...

Page 51: ...al Door Lock and Alarm I O Expansion RS232 Drive 1 Secondary Reader Digital Inputs 3 Digital Outputs 3 Proximity Reader Optional EM 125kHz HID 125kHz MiFare 13 56MHz ISO 14443A B ISO 15693 Power Suppl...

Page 52: ...Center www unitech adc com Unitech Asia Pacific Middle www unitech utp com tw Greater China Division www unitech sbd com Unitech Japan www unitech japan co jp Unitech America www ute com Unitech Latin...

Reviews: