D.7 Code 128 / MSI Code / Code 93 / Codabar/ Label Code
Enter Group 8
Group Default
Code 128:
0/
1
-- Disable/
Enable
1-64 -- Min Length
1
/ Max Length
64
G1
MSI /Plessey Code:
0
/1 --
Disable
/Enable
2/
3
-- Check Digit Send /
No Send
4 -- Check Digit Double Module 10
5 -- Check Digit Module 11 plus 10
6 -- Check Digit Single Module 10
1-16 -- Min Length
1
/ Max Length
16
G2
Code 93:
0/
1
-- Disable/
Enable
1-48 -- Min Length
1
/ Max Length
48
G3
Code 11: (Special)
0
/1 --
Disable
/Enable
2/
3
-- One /
Two
Check Digit
4/
5
-- Check Send /
No Send
1-48 -- Min Length
1
/ Max Length
48
G4
Codabar:
0
/1 --
Disable
/Enable
2/
3
-- Start & Stop Send /
No Send
4 -- Check Digit Calculate & Send
5 -- Check Digit Calculate but not Send
6 -- Check Digit not Calculate
7/
8
-- CLSI Format On /
Off
3-48 -- Min Length
3
/ Max Length
48
G5
Label Code IV and V:
0
/1 --
Disable
/Enable
2/
3
– Checksum send
/ No send
G6
0
1
2
3
4
5
6
7
8
9
Min Length
MM
Max Length
NN
Exit
45
Summary of Contents for MS840
Page 1: ...Wireless Scanner MS840B MS840P MS840 User s Manual Version 1 6 ...
Page 2: ......
Page 8: ...vi ...
Page 12: ...x ...
Page 18: ...6 ...
Page 46: ...34 The output of above input will be ABEL STEVE CR 012345678901234 CR 9001 CR ...
Page 61: ...RS D US E SP A B C F G H I J L 0 1 2 3 4 5 6 7 8 9 Z F G H I 49 ...
Page 62: ... J V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z K L M N _ O 50 ...