5. Power on the computer/host terminal.
6. The MS837 will automatically power on, and a power-up beep will be emitted, when the
computer/host terminal is turned on.
Removing the Interface Cable
Unplug the installed cable’s modular connector by depressing the connector clip with the tip of
a screwdriver.
Bar Code Configuration Methods
The scanner can be bar code configured in two ways: the
Single-Code Method
and the
Multi-Code Method
.
Note:
To properly configure an MS837 scanner, all configuration codes must be scanned
using the CodeGate
®
option.
Single-Code Method
Most features can be enabled or disabled using the Single-Code Method.
1. Power-up the scanner.
2. Scan the bar code for the desired feature.
3. The scanner will emit a multi-toned beep to indicate the configuration has been saved to
NOVRAM.
Multi-Code Method
All features can be enabled or disabled using the Multi-Code Method. A feature marked with a
tilde ( ~ ) requires the Multi-Code Method.
1. Power-up the scanner.
2. Scan the
enter/exit configuration mode
bar code (3 beeps).
3. Scan the bar code for the desired feature (1 beep). Multiple features can be
enabled/disabled before scanning the enter/exit configuration mode bar code.
4. Scan the
enter/exit configuration mode
bar code (3 beeps) and save the new
configuration. To abort a configuration change, power off the scanner before scanning
the
enter/exit
code.
Enter/Exit Configuration Mode
Need To Start Over?
Scan the
Recall Defaults
bar code to erase all previous settings and return the scanner to its
factory default communication protocol. Keyboard Wedge interface scanners will load keyboard
wedge defaults.
Recall Defaults
3