background image

 

Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd. 

 

25 

 

 

3. 1st Set Complete 

 

1. 2nd Set Begin 

 

2. Decimal Value (See Appendix A) 

 

3. 2nd Set Complete 

 

Minimum Length

 

1. Begin 

 

2. Decimal Value (See Appendix A) 

 

3. Complete 

 

6.4 Code 128 Parameters 

A Reading Type

 

UCC/EA1-128 Enable 

 

<UCC/EA1-128 Disable> 

 

<Enable’]C1’Code Format> 

 

Disable‘]C1‘Code Format 

 

 

 

Summary of Contents for MS250

Page 1: ...CCD Barcode Scanner MS250 User s Manual Version 2 0 ...

Page 2: ...ontains propriety information that is protected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Unitech 2013 Unitech All rights reserved Trademarks Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation Other product names mentioned in this manual may be ...

Page 3: ... Communication Parameters 8 5 1 RS232 Communication Parameters 8 5 2 Keyboard Wedge Mode Parameters 10 5 3 Output Characters Parameters 13 5 4 Wand Emulation Mode Parameters 15 Chapter 6 Bar Codes Others 16 6 1 SymboIogies Selection 16 6 2 UPC EANI JAN Parameters 20 6 3 Code 39 Parameters 23 6 4 Code 128 Parameters 25 6 5 Interleave 25 Parameters 27 6 6 IndustriaI 25 Parameters 29 6 7 Matrix 25 Pa...

Page 4: ...Sensitivity of Continuous Reading Mode 49 7 7 Reverse Output Characters 50 7 8 Setup Deletion 50 7 9 Setup Insertion 54 Appendix A Decimal Value Table 58 Appendix B ASCII Table 58 Appendix C Function Key Table 62 8 SPECIFICATION 63 8 1 Dimensions 63 8 2 Technical Data 64 8 3 Readable Symbology 65 8 4 Reliability 66 ...

Page 5: ...Copyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 1 Chapter 1 Quick Tour ...

Page 6: ...rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 2 Chapter 2 Installation and Operation 1 Connect the USB connector of MS 250 to the USB port of a host PC 2 Aim at the barcode and pull the trigger to scan the barcode ...

Page 7: ...Copyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 3 Chapter 3 CONFIGURATION 3 1 Flow Chart ...

Page 8: ... back to the Default Settings just scan label for Set All Defaults 3 3 Factory Default Settings The factory default settings are shown with and bold in the following sections You can make your own settings by following the procedures in this manual If you want to save the settings permanently you should scan the label of Save Parameters in chapter 2 4 otherwise the settings will not be saved after...

Page 9: ...The parameter settings will be saved permanently Recall Stored Parameters Replace the current parameters by the parameters you saved last time Set AII Defaults Set all the parameters to the factory default settings Abort Configuration Terminate current programming status Version Information Display the decoder version information and date code ...

Page 10: ...gistered trademark of unitech Electronics Co Ltd 6 Chapter 4 Interface and Reading Mode Selection 4 1 Interface SeIection USB Mode Keyboard Mode RS232 Mode WAND Emulation Virtual Com Port Mode 4 2 Reading Mode Selection Trigger ON OFF Good Read OFF Continuous Trigger OFF Testing ...

Page 11: ...itech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 7 Continuous Auto Power On Flash Flash Auto Power On Reserved1 Auto Sense Option Reserved3 Reserved4 Reserved5 ...

Page 12: ... rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 8 Chapter 5 Communication Parameters 5 1 RS232 Communication Parameters A Set Up BAUD Rate 1200 2400 4800 9600 19200 38400 B Set Up Data Bits 7 Data Bits 8 Data Bits ...

Page 13: ... Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 9 C Set Up Stop Bits 1 Bit 2 Bits D Set Up Parity None Even Odd Mark Space E Handshaking RTS CTS Enable RTS CTS Disable ...

Page 14: ...erved Unitech is a registered trademark of unitech Electronics Co Ltd 10 ACK NAK Enable ACK NAK Disable XON XOFF Enable XON XOFF Disable 5 2 Keyboard Wedge Mode Parameters A Terminal Type IBM PC AT PS 2 IBM PC XT IBM PS 2 25 30 NEC 9800 Apple Desktop Bus ADB ...

Page 15: ...unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 11 IBM 5550 IBM 122 Key 1 IBM 102 Key IBM 122 Key 2 Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 ...

Page 16: ...nics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 12 B Upper Lower Case No Change Upper Case Lower Case C Caps Lock Detection Enable Disable D Send Character by ALT Method Enable Disable ...

Page 17: ...lectronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 13 E Select Numerical Pad ON OFF 5 3 Output Characters Parameters A Select Terminator CR LF None CR LF Space HT TAB STX ETX ...

Page 18: ...yright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 14 B Time out Between Characters 0 ms 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms ...

Page 19: ...istered trademark of unitech Electronics Co Ltd 15 5 4 Wand Emulation Mode Parameters A TTL Level Representation Bar Equals High Bar Equals Low B Scan Speed Selection Fast Slow C Output Format Selection Output as Code 39 Output as Code 39 Full ASCII Output as Original Code Format ...

Page 20: ... Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 16 Chapter 6 Bar Codes Others 6 1 SymboIogies Selection UPC A ON OFF UPC E ON OFF EAN 13 JAN 13 ISBN 13 ON OFF EAN 8 JAN 8 ON OFF CODE 39 ON OFF ...

Page 21: ...2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 17 CODE 128 ON OFF CODABAR NW7 ON OFF Interleave 25 ON OFF Industrial 25 ON OFF Matrix 25 ON OFF ...

Page 22: ...t 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 18 CODE 93 ON OFF CODE 11 ON OFF China Postage ON OFF MSI PLESSEY ON OFF Code 2 of 6 ON OFF ...

Page 23: ...nics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 19 LCD25 ON OFF Reserved5 ON OFF Reserved6 ON OFF GS1 DataBar Omnidirectional ON OFF GS1 DataBar Limited ON OFF GS1 DataBar Expanded ON ...

Page 24: ...s reserved Unitech is a registered trademark of unitech Electronics Co Ltd 20 OFF Select All Bar Codes 6 2 UPC EANI JAN Parameters A Reading Type UPCA EAN13 ON UPCA EAN13 OFF ISBN 1C Enable ISBN 13 Enable ISSN Enable ISSN Disable Decode with Supplement ...

Page 25: ...is a registered trademark of unitech Electronics Co Ltd 21 Auto discriminate Supplement Expand UPC E Enable Expand UPC E Disable EAN8 EAN13 Enable EAN8 EAN13 Disable GTIN Format Enable GTIN Format Disable B Supplemental Set Up Not Transmit Transmit 2 Code Transmit 5 Code ...

Page 26: ...Unitech is a registered trademark of unitech Electronics Co Ltd 22 Transmit 2 5 Code C Check Digit Transmission UPC A Check Digit Transmission ON OFF UPC E Check Digit Transmission ON OFF EAN 8 Check Digit Transmission ON OFF EAN 13 Check Digit Transmission ON OFF ...

Page 27: ...nitech Electronics Co Ltd 23 ISSN Check Digit Transmission ON OFF 6 3 Code 39 Parameters A Type of Code Standard Full ASCII Italian Pharmacy Code 32 OFF Italian Pharmacy Code 32 ON B Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit Calculate Check Digit Not Transmit ...

Page 28: ...Asterisk Enable Disable E Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 2 Decimal Value See Appendix A ...

Page 29: ...nitech Electronics Co Ltd 25 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value See Appendix A 3 2nd Set Complete Minimum Length 1 Begin 2 Decimal Value See Appendix A 3 Complete 6 4 Code 128 Parameters A Reading Type UCC EA1 128 Enable UCC EA1 128 Disable Enable C1 Code Format Disable C1 Code Format ...

Page 30: ...Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit Calculate Check Digit Not Transmit C Append FNC2 ON OFF D Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional ...

Page 31: ...ength 2 Sets Available 1 1st Set Begin 2 Decimal Value See Appendix A 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value See Appendix A 3 2nd Set Complete Minimum Length 1 Begin 2 Decimal Value See Appendix A 3 Complete 6 5 Interleave 25 Parameters A Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit ...

Page 32: ...dd C Brazilian Banking Code Disable Enable D Set 8p Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Beg 2 Decimal Value See Appendix ...

Page 33: ...unitech Electronics Co Ltd 29 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value See Appendix A 3 2nd Set Complete Minimum Length 1 Begin 2 Decimal Value See Appendix A 3 Compete 6 6 IndustriaI 25 Parameters A Reading type IATA25 Enable Disable B Check Digit Transmission Do Not Calculate Check Digit ...

Page 34: ...set the fixed length 1 Scan the Begin label of the desired set 2 Go the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1 1st Set Begin 2 Decimal Value See Appendix A 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value See Appendix ...

Page 35: ...eters A Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit Calculate Check Digit Not Transmit B Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional l...

Page 36: ...ectronics Co Ltd 32 Fix Length 2 Sets Available 1 1st Set Begin 2 Decimal Value Appendix A 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value Appendix A 3 2nd Set Complete Minimum Length 1 Begin 2 Decimal Value Appendix A 3 Complete 6 8 CODABAR NW7 Parameters A Set Up Start Stop Characters Upon Transmission ON ...

Page 37: ... Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 33 OFF B Transmission Type of Start Stop A B C D Start A B C D Stop A Start A Stop B Start B Stop C Start C Stop D Start ...

Page 38: ... 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1st Set Begin Decimal Value Appendix A 1st Set Complete 2nd Set Begin Decimal Value Appendix A 2nd Set Complete ...

Page 39: ...ission Calculate Check 2 Digits Not Transmit Do Not Calculate Check Digit B Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1st Set Be...

Page 40: ...ech Electronics Co Ltd 36 1st Set Complete 2nd Set Begin Decimal Value Appendix A 2nd Set Complete Minimum Length Begin Decimal Value Appendix A Complete 6 10 Code 11 Parameters A Check Digit Transmission Do Not Calculate Check Digit Calculate Check 1 Digit Transmit Calculate Check 2 Digits Not Transmit ...

Page 41: ...e Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1st Set Begin Decimal Value Appendix A 1st Set Complete 2nd Set Begin Decimal Value Appendix A 2...

Page 42: ...ters A Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit Calculate Check Digit Not Transmit B Set Up Code Length To set the fixed length 1 Scan the Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional le...

Page 43: ...ics Co Ltd 39 Fix Length 2 Sets Available 1st Set Begin Decimal Value Appendix A 1st Set Complete 2nd Set Begin Decimal Value Appendix A 2nd Set Complete Minimum Length Begin Decimal Value Appendix A Complete 6 12 LCD25 Parameters A Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit Transmit ...

Page 44: ...e Begin label of the desired set 2 Go to the Decimal Value Tables in Appendix A scan label s that represents the length to be read 3 Scan the Complete label of the desired set 4 Repeat the steps 1 3 to set additional lengths Variable Fix Length 2 Sets Available 1st Set Begin Decimal Value Appendix A 1st Set Complete 2st Set Begin Decimal Value Appendix A 2nt Set Complete Minimum Length Begin Decim...

Page 45: ...tech is a registered trademark of unitech Electronics Co Ltd 41 Complete Fix Length 2 Sets Available 1st Set Begin Decimal Value Appendix A 1st Set Complete 2nd Set Begin Decimal Value Appendix A 2nd Set Complete Minimum Length Begin Decimal Value Appendix A Complete ...

Page 46: ...ech Electronics Co Ltd 42 6 15 GS1 Databar A GS1 DataBar Omnidirectionl Transmit Check Digit Don t Transmit Check Digit Transmit Application ID Don t Transmit Application ID Transmit Symbology ID Don t Transmit Symbology ID B GS1 DataBar Limited Parameters Transmit Check Digit Don t Transmit Check Digit ...

Page 47: ...rved Unitech is a registered trademark of unitech Electronics Co Ltd 43 Transmit Application ID Don t Transmit Application ID Transmit Symbology ID Don t Transmit Symbology ID C GS1 DataBar Expanded Parameters Transmit Symbology ID Don t Transmit Symbology ID ...

Page 48: ...Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 44 Chapter 7 Miscellaneous Parameters 7 1 Language Selection US English UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese ...

Page 49: ...ghts reserved Unitech is a registered trademark of unitech Electronics Co Ltd 45 Belgium Portuguese Denmark Netherlands Turkey Reserved2 7 2 Bar Code ID ON OFF Default With this function ON a leading character will be added to the output string while ...

Page 50: ...F CODE 39 M CODE 128 K Interleave 25 I Industrial 25 H Matrix 25 I Codabar NW7 N CODE 93 L CODE 11 L China Postage C MSI O LCD25 Q PLESSEY P GS1 DataBar Omnidirectional U GS1 DataBar Expanded W GS1 DataBar Limited V User Define Code ID To set the code ID 1 Scan the symbologies label 2 Go to the ASCII Tables in Appendix B scan label that represents the desired code ID Note User define code ID will ...

Page 51: ...lectronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 47 EAN 8 JAN 8 CODE 39 CODE 128 CODABAR NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 China Postage MSI PLESSEY ...

Page 52: ...eserved Unitech is a registered trademark of unitech Electronics Co Ltd 48 LCD25 GS1 DataBar Omnidirectional ON GS1 DataBar Limited ON GS1 DataBar Expanded ON Reserved5 Reserved6 7 3 Reading Level Bar Equals High Bar Equals Low 7 4 Accuracy 1 Time 2 Times ...

Page 53: ...igh Medium Low Off 7 6 Sensitivity of Continuous Reading Mode A Quick Setting Fast Slow B Same Code Delay Reading Interval Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode The value can be defined from 1 50 and they represent 100ms to 5 seconds in 100ms interval Default value is 3 0 3 seconds ...

Page 54: ... set time out of same symbol Begin Decimal Value 1 50 Appendix A Complete 7 7 Reverse Output Characters Disable Enable 7 8 Setup Deletion To setup the deletion of output characters 1 Scan the label of the desired set below 2 Scan the label of the desired symbology 3 Go to the Decimal Value Tables listed in Appendix A scan labels that represents the desired position to be deleted 4 Scan Complete la...

Page 55: ...nics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 51 A Select Deletion Set Number 1st Set 2nd Set 3rd Set 4th Set 5th Set 6th Set B SymboIogy Selection UPC A UPC E EAN 13 JAN 13 ISBN 13 ...

Page 56: ...lectronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 52 EAN 8 JAN 8 CODE 39 CODE 128 CODABAR N97 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 China Postage MSI PLESSEY ...

Page 57: ...red trademark of unitech Electronics Co Ltd 53 LCD25 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded All Codes None C Character Position to be Deleted 1 Decimal Value Appendix A 2 Complete D Number of Characters to be Deleted 1 Decimal Value Appendix A 2 Complete ...

Page 58: ...cimal Value Tables in Appendix A scan label s that represents the desired position to be inserted 4 Scan the Complete label of Character Position to be Inserted 5 Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C scan label s that represents the desired characters to be inserted 6 Scan the Complete label of Characters to be Inserted 7 Repeat the steps 1 6 to set additional ...

Page 59: ...o Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 55 B SymboIogies Selection UPC A UPC E EAN 13 JAN 13 ISBN 13 EAN 8 JAN 8 CODE 39 CODE 128 CODABAR NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 ...

Page 60: ... Unitech is a registered trademark of unitech Electronics Co Ltd 56 CODE 11 China Postage MSI PLESSEY LCD255 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded All Codes None C Character Position to be Inserted Decimal Value Appendix A Complete ...

Page 61: ...Copyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 57 D Characters to be Inserted ASCII Table Appendix B Complete ...

Page 62: ...s Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 58 Appendix A Decimal Value Table 0 5 1 6 2 7 3 8 4 9 Appendix B ASCII Table NULL STX SOH ETX ENQ EOT ACK BS BEL HT VT LF FF SO CR SI DC1 DLE ...

Page 63: ...pyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 59 DC2 DC4 DC3 NAK ETB SYN CAN SUB EM ESC GS FS RS US SPACE 1 0 2 4 3 5 7 6 8 9 ...

Page 64: ...opyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 60 B A C E D F H G I K J L N M O Q P R T S U W V X Z Y _ b a c e d f h g i k j ...

Page 65: ...Copyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 61 l n M o q p r t s u w v x z y DEL ...

Page 66: ...ronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 62 Appendix C Function Key Table F1 F3 F2 F4 F6 F5 F7 F9 F8 F10 F12 F11 Insert Home Delete Page Up End Page Down Left Up Right Down ...

Page 67: ...Copyright 2012 unitech Electronics Co Ltd All rights reserved Unitech is a registered trademark of unitech Electronics Co Ltd 63 8 SPECIFICATION 8 1 Dimensions ...

Page 68: ...ex M3 32 bit Operating Freq 8 MHz Internal Scan Speed 200 scans second 10 Depth of Field Up to 75mm 20mil PCS90 Code39 Width of Field Window 80 mm Print Contrast Ratio 45 Resolution 3mil 0 076mm PCS90 Ambient Light 20 000 Lux Max Reading Angle Test Conditions Code 39 10mil 0 25mm PCS 90 Forward Backward 10 30 5 Left Right 60 5 Firmware Available for updated Driver Support USB emulation COM port ES...

Page 69: ...EAN128 Code V V Code 39 V V Code 39 Full ASCII V Code32 Italian Pharmacy V Code 128 V V CODABAR NW7 V V Interleave 25 V V Industrial 25 V Matrix 25 V MSI PLESSEY V Code 93 V Code 11 V China Postage V LCD25 V GS1 DataBar Omnidirectional V GS1 DataBar Turncated V GS1 DataBar Stacked V GS1 DataBar Omnidirectional Stacked V GS1 DataBar Limited V GS1 DataBar Expanded V GS1 DataBar Expanded Stacked V ...

Page 70: ...ity Life Time Trigger Switch 1 000 000 times MTBF Calculated 50 000 hours Thermal Shock High Temp 60 o C 140 o F Low Temp 20 o C 4 o F Cycle time 20 minutes for high temp 20 minutes for low temp Cycles 5 cycles Cable Bending Test 25 000 times minimum 30 times min 500g 90 o Drop 59 06 inches 150cm drop on Concrete Surface Beeper 90 db minimum ...

Reviews: