background image

U S E R ’ S      M A N U A L

 

 
 
 

Scantech Sirius S-7030

 

Bar Code Laser Scanner

 

Summary of Contents for Sirius S-7030

Page 1: ...U S E R S M A N U A L Scantech Sirius S 7030 Bar Code Laser Scanner ...

Page 2: ......

Page 3: ...User s Manual Scantech Sirius S 7030 ...

Page 4: ... used in accordance with the user s manual may cause harmful interference to radio communications Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any unauthorized changes or modifications to this equipment could void the user s authority to operate this equipment For CE c...

Page 5: ...unting the scanner plus flexible stand 13 2 4 Controlling the scanner from the POS system 15 2 5 Standard available interface cables 15 2 6 Interface Selection 18 Chapter 3 Using the Sirius S 7030 19 3 1 Orientation 20 3 2 Scanning bar codes with the Sirius S 7030 22 3 3 Single line scanning 23 3 4 Maintaining the scanner 24 Appendices 25 A Connector types and pin definitions 26 B Technical specif...

Page 6: ......

Page 7: ...are has been integrated The Sirius S 7030 is equipped with triple interface for integration in nearly every environment The interface RS 232 Key Board Wedge or USB is selected by the cable connected USB plus power is supported as well The low power consumption makes the Sirius multi connectable The Sirius is available in three different colour schemes and standard supplied with an EAS antenna and ...

Page 8: ......

Page 9: ...Chapter 1 The Sirius S 7030 ...

Page 10: ...cessories for any evidence of physical damage Check with the information of chapter 2 5 that you have got the right interface cable Immediately contact your supplier if anything appears to be damaged or if the supported interface cable does not correspond with the host system interface Optional ATTENTION Details may differ from the illustration above however in functionality it should be identical...

Page 11: ...er is ready to read a bar code A green LED indicates a good read The buzzer is heard whenever a bar code has been read correctly The frequency and volume can be adjusted The rotary and flexible stand allows you to direct the scan pattern in a way that is optimal for your application a mounting kit with screws and tapes is included The scanner can be lifted out for manual scanning This part serves ...

Page 12: ...el is visible through the scanner window All labels are attached by the manufacturer and should not be removed The scanner s serial number and type number are found underneath the scanner as depicted in the figure above This official registration number is strictly related to the device The supplier may ask for these numbers when the scanner needs servicing ...

Page 13: ...rlys i læ ngere perioder Finnish S 7030 skanneri täyttää luokan I lasertuotteelle IEC 825 1 ssä 1993 asetetut turvavaatimukset Se täyttää myös U S 21CFR1040 ssa asetetut vaatimukset siltä osin kuin ne koskevat luokan IIa lasertuotetta Vältä pitkäaikaista suoraan laservaloon katsomista Swedish Avsökaren S 7030 uppfyller säkerhetsnormen IEC 825 1 1993 för laserprodukter av klass 1 Den uppfyller dess...

Page 14: ...light observed at 13 cm 5 1 in above the window through a 7 mm 0 28 in aperture and averaged over 1000 seconds is less than 3 9 µW per CDRH Class IIa specification Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8 mW could be accessible inside Laser Light Viewer The scanner window is the only aperture through which laser light may ...

Page 15: ...Chapter 2 Installation ...

Page 16: ...ting position Now you can lift off the cover If you have an older type of cover press the two little clips on the bottom and carefully shift the end cover downward and take it away Downward is referring to the normal lower side of the scanner if positioned in operating position 2 Make sure the power has been turned off and connect the interface cable to the 10 pin RJ 48 connector of the scanner as...

Page 17: ...using Direct Power or Power Of Terminal This requires that your PC POS system is providing sufficient power on its data port RS 232 USB or KBW See Appendix B for details All applicable Sirius interface cables have a power injector to connect an optional external PSU in the case the POS system does not supply sufficient DC power for the scanner See next page for illustration A standard PC USB port ...

Page 18: ...ower injector in the cable this does not automatically mean that you must use a power supply For safety reasons an automatic switch will disconnect the power provided by the PC POS system as soon as a separate power adapter is connected to the power injector ...

Page 19: ...stand you are advised to precisely follow the next steps 1 Gently pull the bottom disk out of the stand 2 Place the bottom plate on the counter and mark the places for the mounting holes on the counter top and mark the hole to lead the cables through 3 Drill the mounting holes and the lead through hole ATTENTION If you prefer not to drill in your counter you can mount the stand using the provided ...

Page 20: ...the desired position 8 Connect the data cable to the host See note in Chapter 2 2 9 If applicable connect the power supply plug to the power injector Than connect the IEC power cord to the AC DC power supply and plug the AC power cord into an AC power outlet 10 Place the scanner in the desired angle see Chapter 3 1 11 Switch on the host system ATTENTION Once the scanner is installed you can start ...

Page 21: ...t Out or Ctrl N Shift In or Ctrl O DC2 or Ctrl R DC4 or Ctrl T When the scanner is disabled the motor of the scanner will stay on until the scanner goes into sleep mode 2 5 STANDARD AVAILABLE INTERFACE CABLES On the next pages you see the standard available interface cables with some additional information Note that the power injector may be used to insert the DC power from the optional external p...

Page 22: ...ion DP EP A201902 Cable RS 232 Wincor Beetle POS Sub D 9 pin Male DP EP A201903 Cable RS 232 PC POS Sub D 9 pin Female DP EP A201904 Cable RS 232 Fujitsu ICL TeamPOS Sub D 9 pin Female DP EP A201906 Cable RS 232 IBM 4614 Sure One Sub D 15 pin Male DP EP ...

Page 23: ...us USB must be directly connected to the PC USB port and not through an un powered USB hub A201908 Cable USB plus power Green 8 pin connector DP A201508 Gender Changer KBW PC DIN adapter DP means Direct Power Power Of Terminal EP means External Power through the optional PSU 17 ...

Page 24: ...e International Keyboard lay out ALT method for communication in the most versatile way Settings may be changed to some national keyboards if required using the Configuration Guide Chapter 3 4 In RS 232 mode the default communication parameters are 9600 N 8 2 Using the Scantech Configuration Guide Chapter 3 1 you may select one of the various presets or set each parameter by hand In USB mode the s...

Page 25: ...Chapter 3 Using the Sirius S 7030 ...

Page 26: ...ION Using the Sirius S 7030 See the picture below to get acquainted with the various parts of the scanner Red LED Ready Green LED Good Read Button Wake Up or Single Line Rubber Grips Data Power Cable Stand adjustable ...

Page 27: ...h that the beam pattern is projected optimally onto the products you present for scanning To scan barcodes on large or difficult to reach objects you may lift the scanner from its stand and use the scanner as a hand scanner In the standard configuration the scanner is scanning continuously so you do not need to trigger like with a traditional hand scanner Rocking the scanner Foot rotation ...

Page 28: ... Hands free scanning by presenting the item to the scanner Handheld scanning by taking the scanner out of the stand and aiming it to the barcode label on the products ATTENTION Since the Sirius is a presentation scanner best results are obtained if the barcode is moved towards the scanner or move the scanner towards the barcode The scanner s scan volume is illustrated in the figure below The optim...

Page 29: ... and the data is transmitted The scan line will blink as a confirmation of good read and as a warning that the single line mode will stop unless you press the button again 4 If you press the button again during the blinking period you can start scanning another barcode using single line ATTENTION If you need to scan many barcodes sequentially in Single Line mode you can best press the button again...

Page 30: ... The Sirius S 7030 scanner requires little maintenance Only occasional cleaning of the scanner window is necessary to remove dirt or fingerprints Cleaning can be performed during operation with a non abrasive glass spray cleaner and a soft lint free cloth ...

Page 31: ...Appendices A Connector types and pin definitions B Technical Specifications C Troubleshooting ...

Page 32: ...lity In case you need a special interface cable you can use the information below Pin definitions for multi interface Connector RJ 48 10 pins Multiple Interface RS 232 KBW USB Pin Description Description Description Remark 1 2 3 4 5 6 7 8 9 10 CTS RxD TxD RTS Ground 5 2V D Power PC Clock PC Data KB Data KB Clock Ground 5 2 V D Power IFID connect to Pin 6 IFID IFID connect to Pin 1 Ground 5 2 V D P...

Page 33: ...Appendices Pin definition EAS connector EAS Pin Description Direction 27 1 2 The EAS connection is used to connect the internal deactivation antenna to an external EAS control unit ...

Page 34: ...stand 5 2 Vdc 260 mA or 8 16Vdc max 2VA RS 232 KBW and USB USB plus power Visible laser diode 630 670 nm Approx 200 mm 8 inches EAN UPC 100 Max range approx 300mm 12 EAN UPC 200 5 directions scan field 20 lines scan pattern plus Single Line option 1350 scans second EAN UPC JAN Add on Code 128 EAN 128 Interleaved 2 5 MSI Plessey Code 93 Code 39 Code 39 full ASCII Code 32 Italian Pharmacode Codabar ...

Page 35: ...e 94V 0 EM Compatibility 29 EMC EN 61000 6 3 2001 Generic emission standard from which EN 55001 1998 Emission class B EN 61000 6 2 2001 Generic immunity standard from which EN 61000 4 2 1995 Electrostatic Discharge ESD Immunity EN 61000 4 3 1996 Radiated Electro Magnetic field immunity ENV 50204 1995 Digital radio telephones immunity EN 6100 4 4 1995 Electrical Fast Transient EFT Immunity EN 61000...

Page 36: ...accept more than two or three bar codes Diagnostic Tips The scanner window is dirty Clean the scanner window as described in the Maintenance section The presented bar code type is not enabled Select the bar code type with the Configuration Guide The scanner is disabled by the host Refer to Section 2 4 The bar code type you presented to the scanner is not supported by the Sirius The scanner is in s...

Page 37: ...r cannot send the data to the host system There is no proper handshaking between the scanner and the host Scanner buffer is full Make sure that all cables are connected and your host system is ready to receive data The communication cable is not connected to the serial port of your host system Refer to the manual of your host system to locate the serial port The communication settings of the host ...

Page 38: ...m the Configuration Guide In case of KB emulation in combination with the ALT input method check if Num Lock of your keyboard is on In a MS Windows environment verify with the device manager that a HID Human Interface Device is installed for the scanner Check that scanner and POS system or Computer have both been set for the same USB protocol KB emulation COM Port emulation or IBM POS protocol See...

Page 39: ......

Page 40: ...Scantech ID BV Amersfoortsestraat 124 3769 AN Soesterberg The Netherlands Phone 31 0 33 469 84 00 Fax 31 0 33 465 06 15 E mail info scantech id com Internet www scantech id com ...

Reviews: