Page 3: ...Installation User s Manual Scantech ID LIBRA L 7050 Multi purpose Omni directional scanner ...

Page 4: ...on to notify any person or entity of the revision or change A serial number appears on the product Make sure that this official registration number has not been removed It should be used whenever servicing by Scantech ID BV or an authorized Scantech dealer is necessary Important This equipm ent has been tested and found to comply with the limits for a Class B digital device pursuant to EN55022 and...

Page 5: ...Installation 7 2 1 UNPACKING 8 2 2 CONNECTING 10 2 3 ADJUSTING 11 2 4 POWERING 12 2 5 INITIALIZING 13 Chapter 3 Using LIBRA 15 3 1 SCANNING BARCODES 16 3 2 CONTROLLING 17 3 3 MAINTAINING 17 Chapter 4 Applications 19 Appendices 21 A CONNECTOR TYPES AND PIN DEFINITIONS 22 B TECHNICAL SPECIFICATIONS 23 C TROUBLESHOOTING 25 ...

Page 6: ......

Page 7: ...deal to use in check out services Features Integrability The compact design allows the unit to be mounted with ease on a host system with minimum space requirement Quality and Durability The components are of top quality and the case is solid moist and dust resistant All of these secure a long and service free operation time Durable characteristic with IP42 rating and drop resistance with cable Au...

Page 8: ...apter provides the product safety information The second chapter describes LIBRA s general features and installation The third and forth chapters account for the use of LIBRA The connector types and pin definitions technical specifications and troubleshooting can be found in the appendices ...

Page 9: ...Chapter 1 Product Safety ...

Page 10: ...3 9 µW per CDRH Class IIa specification Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8 mW could be accessible inside Laser Light Viewer The scanner window is the only aperture through which laser light may be observed on this product A failure of the scanner motor while the laser diode continues to emit a laser beam may cause em...

Page 11: ...roduct LIBRA Model number L 7050 and equivalent Product View Will comply with the following product specifications Laser Safety IEC60825 1 CFR 1040 Class IIa CDRH Electrical Safety EN 60950 1 2001 EMC EN 55022 2006 A1 2007 EN 61000 3 1 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EN 55024 1998 A1 2001 A2 2003 Please note that a ScanTech ID CE marked power supply unit should be used to confirm the produc...

Page 12: ...ated in the illustration below All labels are attached by the manufacturer and should not be removed The information about the serial and part numbers can be found on the product label These official registration numbers are strictly related to the device The supplier may ask for these numbers when the scanner needs servicing ...

Page 13: ...Chapter 2 Installation ...

Page 14: ...ed See 2 4 Powering on page 11 4 Configuration Guide Use to configure LIBRA with barcodes 5 User s Manual Provides installation and use instructions NOTE If anything is missing or appears to be damaged immediately contact your dealer You can mount LIBRA without the fit plate but the plate may be suitable for your special mounting requirements Contact your dealer for more information Store the orig...

Page 15: ...e Successful read 2 Window Reads the bar code placed in front of the window 3 Buzzer Beeps when data is read correctly 4 Cable hook Use to align the cable NOTE LIBRA beeps whenever data is read correctly Both frequency and volume can be adjusted see section 2 1 1 Speaker frequency and 2 1 2 Speaker volume on the Configuration Guide ...

Page 16: ... Powered USB On powering up the scanner determines the type of the interface used and switches to the appropriate protocol Interface Cable Connector type RS232 Product Number 0114 SM01121 Sub D 9 pin Keyboard Wedge Product Number 0114 SM02121 Standard PS2 USB Product Number 0114 SM04121 USB connector Powered USB Product Number 0114 S801121 Powered USB connector ...

Page 17: ...Remove the attached cable 3 Connect the desired interface cable to LIBRA Wall hooks 4 Align the cable through the cable hook 5 Connect the other end of the interface cable to your host system 6 If necessary mount the scanner on the wall using the wall hooks 2 3ADJUSTING LIBRA s angle can be adjusted To do this hold LIBRA by its back and adjust the angle as shown below Front angle 22 max Back angle...

Page 18: ...for the scanner Power injector 5V AC adapter Cable Power injector RS232 Keyboard Wedge Powered USB USB NOTE Though some cables have a power injector this does not mean that you must use a power supply For safety reasons an automatic switch will disconnect the power provided by the host system as soon as a separate power adapter is connected to the power injector Changeable power plugs To change th...

Page 19: ...he procedure again KBW mode In KBW Keyboard Wedge mode the scanner defaults to the International Keyboard layout ALT method for communication NOTE To change the settings to national keyboards in KBW mode refer to section 3 4 on the Configuration Guide RS232 mode In RS232 mode the default communication parameters are 9600 N 8 2 Using the Scantech ID Configuration Guide you may select one of the var...

Page 20: ...ther available USB communication selections are USB IBM fixed POS scanner USB IBM handheld scanner emulation USB COM port emulation NOTE See section 3 5 USB communication on the Configuration Guide for more information ...

Page 21: ...Chapter 3 Using LIBRA L 7080i ...

Page 22: ... with a 24 line scan pattern Barcode labels can easily be read by presenting them to the scanner NOTE Since LIBRA is a presentation scanner best results are obtained if the barcode is moved towards the scanner LIBRA s scan volume is illustrated in the figure below The scan depth varies depending on the size of the barcode ...

Page 23: ...nable cancels disable Shift Out or Ctrl N 0F Hex Disable Shift In or Ctrl O 12 Hex Sleep DC2 or Ctrl R 14 Hex Wake cancels sleep DC4 or Ctrl T NOTE More commands are available upon request Please contact your dealer for more information 3 3MAINTAINING LIBRA requires little maintenance Only occasional cleaning of the scanner window is necessary to remove dirt and fingerprints Cleaning can be perfor...

Page 24: ...Chapter 4 Applications ...

Page 25: ...ll payment for services law firms shipping companies enterprises distributors manufacturers hospitals etc The benefits of bar coding are obvious improved data accuracy and accessibility enable a company to make correct decisions about future needs and actions Consequently profits are up Case Benefits of Bar Coding for Retail Stores Building a competitive infrastructure Synchronizing supply with de...

Page 26: ...Appendices A Connection Types and Pin Definitions B Technical Specifications C Troubleshooting ...

Page 27: ......

Page 28: ...al purpose cable you can refer to the information below The Connector type of LIBRA RJ 48 10 pins Pin Definition for multiple interface Multiple Interface RS 232 KBW USB Powered USB Pin Description Description Description Remark 1 IFID IFID Interface ID 2 CTS PC Clock 3 RxD PC Data 4 TxD KB Data IFID Interface ID 5 RTS KB Clock 6 Ground Ground Ground Ground 7 5V 5V 5V 5V may be used to power scann...

Page 29: ... nm visible laser diode Depth of field Up to 230 mm 0 33mm 13mil PCS 90 Code39 Resolution 4mil 0 1mm PCS 90 Code39 Scan pattern 6 direction scan field 24 lines scan pattern Scan rate 2 000 scans per second Light level Up to 4 800 LUX Barcode types Automatically discriminates standard 1D bar codes include GS1 Databar family Omnidirectional Omnidirectional stacked Expanded Expanded stacked Truncated...

Page 30: ...Black Scanner Base or Beige scanner Dark Grey base Environmental Operating Temperature 0 C 40 C Storage Temperature 20 C 60 C Humidity 5 95 RH non condensing dew Safety Laser Safety Class I IEC60825 1 U S 21CFR1040 Class IIa Electrical Safety EN 60950 1 2001 EM Compatibility Radio and TV Interference EN 55024 22 FCC Part 15 class B CNS 13438 Electro Static Discharge IEC 801 2 1991 ESD ...

Page 31: ...s disabled by the host Refer to section 3 2 The barcode type you presented to the scanner is not supported by LIBRA The scanner does not accept more than two or three barcodes There is no proper handshaking with the host system Switch the host system on and check connection and communication settings A barcode is read by the scanner but not accepted by the host system The communication cable is no...

Page 32: ... installed for the scanner Check that the scanner and the host system both expect the same USB protocol KB emulation RS232 emulation or IBM POS protocol See the Configuration Guide for setup codes and reset the scanner after making any changes When using a standard USB cable the scanner defaults to the USB KB emulation protocol with ALT method character transmission When using USB plus power cable...

Page 33: ......

Page 34: ......

Reviews: