2. Product specifications
Detection method:
Optical sensor
Power supply:
Sealed battery (3V DC)
Battery life:
10 years
Sound pressure level:
≥
85 dB (A) at a distance of 3 metres
Alarm sensitivity:
0.105 - 0.155 dB/m
Monitoring range:
40 m²
Operating temperature:
0 °C - 40 °C
Air humidity during operation:
< 93 %
Recommended replacement date:
See product label
Individual alarm display:
Yes
Alarm muting:
Yes | Muting time: 5-15 minutes
Low battery warning indicator:
Yes
Alarm muting in event of
low battery level:
Yes | Muting time: 10 hrs.
Installation in habitable
recreational vehicles:
Yes
Installation location:
Ceiling or wall
Interconnectable: No
3. Warning notices
• To avoid injury, this device must be securely fastened to the ceiling/wall as per the
installation instructions.
• Batteries should not be exposed to excessive heat such as sunlight, fire or the like.
• Do not paint over or cover the smoke alarm.
4. In which areas should smoke alarms be installed
Smoke alarms must be installed in such a way that the fire smoke can reach the smoke alarm
unhindered, so that fires can be reliably detected in their early stages.
• Install in bedrooms (especially children’s rooms) at the very least.
• Install in escape routes at the very least.
• Mount in the middle of the room ceiling.
• Keep a minimum distance of 50 cm from walls and other objects.
• Maximum installation height 6 metres.
• If ceiling mounting is not possible, the smoke alarm can be mounted on the wall. The distance to
the ceiling should be between 30 and 50 centimetres.