H y d r a u l i c
R o t a r y H a m m e r D r i l l
2 2 4 2 6 0 0 1 0
Translation of the original manual,
compiled: 24.02.17
224260010_BA_en_Version_CSU_00
Page 15 of 18
Furthermore we recommend a general overhaul of your hydraulic rotary hammer drill once a year at the
manufacturer, as well as a regular maintenance of the hammer mechanism.
Follow the procedure:
Loosen the socket head screws item 1 and remove the cover item 3 (see fig. 4).
Spray all moving parts with multi-oil-spray: Spitznas order no.: 9 9902 0120 (oder similar).
Replace all sealings item 2, 4 and 5, re-assemble the cover and tighten the screws.
Item
Qty.
Order number
Description
1
2
9 1112 2020
Socket head
screw
2
2
9 1908 1950
Sealing U shape
3
1
2 2404 4090
Cover
4
1
9 1901 3500
O-Ring
5
1
2 2404 4190
Sealing
Fig. 4
After completing maintenance and repair work and before restarting production make sure that…
all materials, tools and other equipment which are required for maintenance or repairs have been
removed from the work area of the machine,
any fluid leaks have been removed,
all safety devices on the machine have proper function,
fixtures of screw connections are tight,
removed covers, screens or filters were reinstalled.
The employer ensures that all maintenance, inspection and assembly work is done by authorized and
qualified experts.
Disassembly- Re-assembly
Maintenance and repair
Disassembly and re-assembly should be done according to the exploded views, respectively the sectional
drawings (see repair instruction).
All work regarding disassembly and re-assembly, have to be executed by SPITZNAS or skilled staff only.
DANGER
–
Working with the machine without appropriate preparation and disregarding of
instructions. Shut down the machine properly and let it cool down to the ambient temperature.
NOTICE – Special instructions apply for the repair of explosion-proof machines.
Retrofits or modifications of the machine need the manufacturer’s acceptance.
The explosion-proof machine is designed in the type of protection „c“ constructive safety.
All work executed on the machine, influencing the explosion protection, e. g. repairs with
mechanical machining, require an approval of an authorized expert or have to be done by the
manufacturer.
The internal structure must remain unmodified.
1
2
3
4
5