Capacity
Pints per day @ 80°F DBT/60% RH
130
Unit Power Supply
Volts/Phase/Hz
115/1/60
Minimum Circuit Ampacity
13.1
Maximum Fuse
15 amp
Dimensions
Length (overall)
30.00 in.
(includes duct collars)
Length (cabinet only)
24.00 in.
Width
25.25 in.
Height
20.50 in.
Weight
Pounds net
150
Compressor
Qty/Type
1/Rotary
Watts/RLA/LRA
1070/9.5/61
Refrigerant
R22
Fan Motor
Qty/HP/FLA
1/0.1/1.15
Air Flow
CFM @ .6 in. w.c. e.s.p.
400
Filter
Type/size(in.)
Washable nylon/17x23.5
Cabinet Insulation
Type/thickness
EPDM/1 in.
R Value
4.2
Duct Connection
Inlet/Outlet
8 in. diameter duct
Drain Pan
Material
Stainless steel
STORAGE
Temporary storage must be indoors, upright in the
original carton, and completely shielded from
precipitation.
INSTALLING THE EQUIPMENT
UNIT LOCATION
Unit location is very important as it will determine
the overall length of the connection ducts. Locate
the unit as close as possible to the indoor portion
of the resident’s air conditioning unit or air
handling unit, in the attic, basement, garage, or
equipment room. The dehumidifier may be placed
above, below or level with the air handing unit;
however, removal of condensate must be
considered when determining the location.
If the unit is mounted above a ceiling or in an
attic, a secondary drain pan under the entire unit
is recommended. This pan should have a visible
overflow drain that will alert the end user that a
problem exists with dehumidifier’s primary
drainage system.
SPECIFICATIONS
Place the unit in a location that will allow a
minimum of 22" clearance for filter removal and
service access. This clearance is required on only
one side of the unit since the filter is removable
from either side. Allow adequate clearance to
walls for normal unit service.
CAUTION!
Do not install the unit outdoors or in a
location where it will be subjected to
precipitation of any kind.
MOUNTING
The unit may be mounted on a flat surface or
suspended. If mounted on a flat surface use the
four rubber mounting feet provided. To minimize
unwanted vibration select a level mounting
surface. Adjust the four mounting feet to
compensate for any irregularities in the surface.
Ensure that the unit is sitting on all four feet. To
suspend the unit a separate hanger kit (S1-DEHUHGKIT)
is required. This kit consists of four brackets and
four rubber isolators. Threaded rod or other
means of suspension must be provided by the
installing contractor and must be selected based
on the unit weight, in compliance with local codes.
3