Unisys Remote Worker Kit User Guide
4
Environmental
Conditions
Operating Temperature: 0°C to 40°C
Operating Humidity: 10% to 95% non-
condensing
Storage Temperature: -40°C to 80°C
Storage Humidity: 5% to 95% non-
condensing
Antenna
type
4 x internal dual-band Wi-Fi antenna
Mounting
Desktop
Wireless Specifications
Standards
2.4GHz 802.11b/g/n/ax
5GHz 802.11a/n/ac/ax
Supported Rates
802.11ax: 4 to 2400 Mbps
802.11ac: 6.5 to 1732 Mbps
802.11n: 6.5 to 600 Mbps
802.11a: 6 to 54 Mbps
802.11g: 6 to 54 Mbps
802.11b: 1 to 11 Mbps
Radio Chains
4 x 4:4
Spatial Streams
4 for both SU-MIMO & MU-MIMO
Antenna
Up to 5.0 dBi
Max Phy Rate
2.4GHz: 1148 Mbps
5GHz: 2400 Mbps
Maximum transmit
power
2.4 GHz: Up to 27dBm (combined power)
5 GHz: Up to 27dBm (combined power)
Minimum receiver
sensitivity
2.4GHz HT20/VHT20/HE20: -93dBm @MCS0
2.4GHz HT40/VHT40/HE40: -94dBm @MCS0
•
5GHz VHT20/HE20: -95dBm @ MCS0
5GHz VHT40/HE40: -93dBm @ MCS0
5GHz VHT80/HE80: -89dBm @ MCS0
Max Number of Clients
Up to 128 per radio
SSIDs
Up to 4 per radio