 2.4

Dimensions 

 
KENTUCKY  HOT GN1 

 

 

 
KENTUCKY  HOT GN2 

 

 

KENTUCKY  HOT GN3 

 

 

KENTUCKY HOT GN 4 

 

Summary of Contents for KENTUCKY COLD GN4

Page 1: ...Heated top table counter K E N T U C K Y H O T Operating manual...

Page 2: ...dance intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with it...

Page 3: ...ust be stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects o...

Page 4: ...permission of the manufacturer is deemed inappropriate purpose For any damage resulting from such an activities the equipment manufacturer is not liable the risk is covered by the user solely Before...

Page 5: ...OPERATING MANUAL FOR KENTUCKY HOT 3 2 4 Dimensions KENTUCKY HOT GN1 KENTUCKY HOT GN2 KENTUCKY HOT GN3 KENTUCKY HOT GN 4...

Page 6: ...OPERATING MANUAL FOR KENTUCKY HOT 4 KENTUCKY HOT GN2 High KENTUCKY HOT GN3 High More of technical information can be found in Chapter 9...

Page 7: ...adjustable feet with wrench nr 24 into horizontal position After the establishment secure the position of the feets by tightening the nut wrench nr 17 2 Insert shelf consoles 3 Insert grids to shelves...

Page 8: ...sing the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate the control panel buttons by using fingers exclusively U...

Page 9: ...nts in the exhibition space up to the highest shelf Heated air is thus injected into all display levels toward the rear doors The air is sucked through grids disposed at sides of the exhibition area a...

Page 10: ...lay case and raises its temperature The front exhaust and side vents must not be covered by goods or other items Also the space between the containers shelves and the rear sliding door must remain fre...

Page 11: ...d container water tray Cleaning 6 2 Regularly The power supply cable Control 6 3 Space around and under unit Cleaning 6 1 Daily maintenance Daily clearing of exhibition space from the remnants of the...

Page 12: ...ustable feets in contact with the floor Are not other devices contiguous or follow too closely of the unit s furniture Does not the unit vibrate too much Is not the showcase in contact with other unwa...

Page 13: ...tually incorrect repairs as well as defects which have been caused by foreign intervention or force majeure 8 DISPOSAL Once the service life of showcase expired it must be properly disposed of During...

Page 14: ...N 1 1 20mm Temperature C 30 90 30 90 30 90 30 90 Voltage V Hz 230 50 230 50 230 50 230 50 Power W 1049 2061 2130 2061 Weight kg 43 57 70 78 GN3 High GN4 1S s s 1S s s High Dimensions mm 1080 x 775 x 7...

Page 15: ...os Name 1 Producer 4 Serial number 2 Contact 5 Technical data 3 Model 6 Production date UNIS COOL s r o Na Ba tici 201 739 01 Star M sto District Fr dek M stek Czech Republic Tel 420 558 655 211 Fax 4...