background image

                         OPERATING MANUAL FOR 

KENTUCKY HOT

 

 

 

 

10 

 

 6.3

Regular maintenance

 

Dirt can impede the exchange of heat between the unit and the environment, which causes an increase in electricity 
consumption and shortens the life of the equipment. Thus, 

each month clean the space under and around unit

.  

 
Regularly check the 

power cable

  
• Pull out the cord from the power supply socket.  

 
• The cable must be in perfect condition, unbroken and untwisted. If there is any damage it must be repaired or 

replaced by a qualified person immediately. 
 

6.4

Troubleshooting 

 

PROBLEM 

CHECK 

The unit does not heat 

 Is not the current supply interrupted? 

 Is not the power cord damaged? 

 Is not the plug of power cord pulled out of the power supply socket? 

 Are not the fuses or circuit breaker blown? 

Showcase heat a little 

 Is the correct temperature set? 

 Are not the circulation of heated air or intake grids blocked by goods? 

 Are not the goods too close together?  

 Are not the doors opened or their opening frequency too high? 

 Are not the fan grids or front vents clogged with dust or other impurities? 

Showcase produces 

excessive noise 

 Are all adjustable feets in contact with the floor?  

 Are not other devices contiguous or follow too closely of the unit's furniture? Does not 

the unit vibrate too much? 

 Is not the showcase in contact with other unwanted objects? 

On the outer surface of 
the case is 
condensation (water) 

Condensation on the outer surface of the display case can occur during cold, humid day, or 
depending on the site of installation. It occurs when there is high humidity of ambient air 

and water from the cold air is coming into contact with hot surfaces. This is normal. In this 
case, wipe the showcase with a dry cloth. 

The inner surface is 
covered by enormous 

condensation 

Before putting in it is recommended to keep the food which have been taken out from combi 
oven or pot outside for some time. Any hot food produce steam and it may condensate on 

inner glass. 

Showcase works, but 
light does not light 

 Are the the lights on? (control panel, button 2)  

 Is the LED strip or its cable damaged? If so, contact service. 

 

If you meet the above conditions and showcase still does not work, unplug showcase from the power supply and call your 
supplier. 

 

 

 

Power failure:

 

Showcase turns on automatically after a power failure.  

 

 

The showcase can be repaired by the authorized service only. 

In case of improper or unauthorized service warranty 

does not apply!

 

 

 
 

 
 

 
 

 
 

 
 

 
 

 

Summary of Contents for KENTUCKY COLD GN4

Page 1: ...Heated top table counter K E N T U C K Y H O T Operating manual...

Page 2: ...dance intended This manual is intended for all persons who come into contact with the device during the installation operation and maintenance Each of these persons must be thoroughly familiar with it...

Page 3: ...ust be stored under the following conditions 1 Showcase should be kept in their original packaging in a dry and dark place 2 Do not turn upside down nor to side the showcase Do not place any objects o...

Page 4: ...permission of the manufacturer is deemed inappropriate purpose For any damage resulting from such an activities the equipment manufacturer is not liable the risk is covered by the user solely Before...

Page 5: ...OPERATING MANUAL FOR KENTUCKY HOT 3 2 4 Dimensions KENTUCKY HOT GN1 KENTUCKY HOT GN2 KENTUCKY HOT GN3 KENTUCKY HOT GN 4...

Page 6: ...OPERATING MANUAL FOR KENTUCKY HOT 4 KENTUCKY HOT GN2 High KENTUCKY HOT GN3 High More of technical information can be found in Chapter 9...

Page 7: ...adjustable feet with wrench nr 24 into horizontal position After the establishment secure the position of the feets by tightening the nut wrench nr 17 2 Insert shelf consoles 3 Insert grids to shelves...

Page 8: ...sing the showcase If the device is damaged in any way turn it off immediately unplug it from the power supply and contact your supplier Operate the control panel buttons by using fingers exclusively U...

Page 9: ...nts in the exhibition space up to the highest shelf Heated air is thus injected into all display levels toward the rear doors The air is sucked through grids disposed at sides of the exhibition area a...

Page 10: ...lay case and raises its temperature The front exhaust and side vents must not be covered by goods or other items Also the space between the containers shelves and the rear sliding door must remain fre...

Page 11: ...d container water tray Cleaning 6 2 Regularly The power supply cable Control 6 3 Space around and under unit Cleaning 6 1 Daily maintenance Daily clearing of exhibition space from the remnants of the...

Page 12: ...ustable feets in contact with the floor Are not other devices contiguous or follow too closely of the unit s furniture Does not the unit vibrate too much Is not the showcase in contact with other unwa...

Page 13: ...tually incorrect repairs as well as defects which have been caused by foreign intervention or force majeure 8 DISPOSAL Once the service life of showcase expired it must be properly disposed of During...

Page 14: ...N 1 1 20mm Temperature C 30 90 30 90 30 90 30 90 Voltage V Hz 230 50 230 50 230 50 230 50 Power W 1049 2061 2130 2061 Weight kg 43 57 70 78 GN3 High GN4 1S s s 1S s s High Dimensions mm 1080 x 775 x 7...

Page 15: ...os Name 1 Producer 4 Serial number 2 Contact 5 Technical data 3 Model 6 Production date UNIS COOL s r o Na Ba tici 201 739 01 Star M sto District Fr dek M stek Czech Republic Tel 420 558 655 211 Fax 4...

Reviews: