27
ADJUSTING THE TOP BURNER AND OVEN FLAME
Keep appliance area clear and free from combustible materials, gaso-
line, and other fl ammable vapors and liquids. Do not obstruct the fl ow
of air that is necessary for combustion and ventilation.
Top Burner Valves
The top burners have orifi ces that are dedicated to the type of fuel to be used.
These orifi ces are not adjustable. They must be changed completely to convert
from one gas to the other. DO NOT DISCARD THE UNUSED ORIFICES. They
should be saved in order to convert the range back to its original fuel.
When converting the gas valves, the minimum fl ame adjustment screw must be
adjusted.
Please see the supplied screwdriver in the conversion kit along with the orifi ces.
The proper fl ame size is approximately 1/4” (0.6 cm) obtained. – see adjustment
procedure below.
The properly adjusted maximum fl ame is approximately 3/4” (1.9 cm) high and
has three distinct cones; the kindling point, the dark blue center cone, and the
outer mantel.
ADJUSTING THE TOP BURNER FLAME
1. Ensure the range has gas supply and power
2. Light the burner
3. Set the top burner valve to the minimum position
4. Remove the knob by pulling straight out
5. Pull insulation to the left of the valve shaft to reveal the bracket screw (fi g 3.)
6. Remove the screw from the bracket using a Philips screw driver, now you have
full access to the bypass screw
Insert the fl at head screwdriver
(2.5mm x 75mm - provided) into
the screw hole and turn the by
pass screw clockwise to adjust
the fl ame
Do not overtighten
6. Replace the knob
7. Repeat for each of the other burners