47
7) LACK OF DRY PERFORMANCE
◎ Situation : after drying, the clothes still get wet.
cause) ☞ The laurdry amount is more than the recommendation capacity 7.0kg.
☞ Condensing cold water is not supplied.
☞ Clogging Bellows Duct results in poor air circulation.
checking method)
◎ Situation aftering drying, the clothes was soaked and hot.
cause) ☞ The dry is done from bad spin performance because of unbalance.
☞ no spin was done before the dry had started.
◎ Situation : PCB shows "H1" or "H3".
cause) ☞ Thermistor is broken.
☞ Thermistor is short or cut-off.
countermeasures) ☞ replace the Thermistor.
part name
checking point
checking results
jurge
repair method
BELLOWS
DUCT
VALVE INLET
+Condensing
HOSE
clogging
bellows duct
no water supply
from inlet valve
heater was
overheated
owing to poor air
circulation
VALVE INLET
connector slipped
out
VALVE INLET
broken
ill-connection of
condensing hose to
duct pipe
clean the bellow
duct
connect normally
replace valve inlet
connect normally
BELLOW
DUCT
VALVE
INLET
CONDENSI
NG HOSE