48
◎ Situation : PCB shows "H7".
cause)
☞ Dry heater is cut-off.
☞ Fuse temp. is cut-off.
repaire method) ☞ replace the Dry heater.
☞ replace the Fuse temp.
checking point
part name
checking results
repaire method
HEATER
SENSOR TEMP.
FUSE TEMP.
dry Heater is short or cut-off.
Thermistor is short or cut-off.
FUSE TEMPERATURE is cut-off.
replace the
dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
HEATER
THERMISTOR
FUSE TEMPERATURE