5) TROUBLE SHOOTING OF DRY SYSTEM
◈
◈ H
HE
EA
AT
TE
ER
R D
DR
RY
Y
Function : heating the air during dry
◎ FAILURE MODE : * "H7" - The air cannot be heated to 10℃ during 2 min.
◎ CHECKING METHOD : * Check the resistance of heater coil and replace with new one.
◈
◈ T
Th
he
errm
miisstto
orr
Function : sensing the air temperature.
◎ FAILURE MODE : * The air cannot be heated even though water is supplied.
* "H1" - shot or cut-off
* "H3" - air temp. is reached over 150℃
◎ CHECKING METHOD : * Check the resistance of thermistor, replace with new one.
◈
◈ F
FU
US
SE
E T
TE
EM
MP
PE
ER
RA
AT
TU
UR
RE
E
function : protecting from the fine hazard or overheating, if the temp., rises over 128℃, power supply will
be cut-off.
◎ Pictures
◎ FAILURE MODE : Dry is not performed.
◎ CHECKING METHOD : Check if fuse is short, and replace with new one.