SAGEON PSMC I PRODUCT MANUAL
PM990-2999-00, Rev 5
4-3
Note:
Any LED that is not illuminated indicates a SAGEON PSMC I internal circuitry failure
requiring a service call to repair.
When completed, press “
Next
” or “
Previous
” to access other test modes. Press “
Escape
” to return
to the main menus or the idle display screen.
4.6 LCD TEST MODE
Press “
Select
” when the display reads “
LCD
OFF
” to activate all of the front panel alphanumeric
LCD segments at once. All of the LCD segments in the 2 by 16 matrix should be on during the test.
Each segment consists of a square of pixels on the screen. Be sure each segment's pixels are on.
Note:
The LCD’s test will automatically end after approx. 10 seconds. Press “
Select
” again, if
desired, to start the test again.
Note:
Any LCD segment or pixel that is not illuminated indicates a SAGEON PSMC I internal
circuitry failure requiring a service call to repair.
When completed, press “
Next
” or “
Previous
” to access other test modes. Press “
Escape
” to return
to the main menus or the idle display screen.
4.7 ALERT TEST MODE
Press “
Select
” when the display reads “
ALERT OFF”
to activate the internal audible alert buzzer.
The display changes to “
ALERT ON”.
The Alert should be heard now although it may not be heard
in noisy environments like Central Offices.
Note:
The Alert test will automatically end after approx. 10 seconds. Press “
Select
” again, if
desired, to start the test again. No sound coming from the Alert in a quiet environment
indicates a SAGEON PSMC I internal circuitry failure requiring a service call to repair.
When completed, press “
Next
” or “
Previous
” to access other test modes. Press “
Escape
” to return
to the main menus or the idle display screen.