![Unipower Quick-Set PowerCassette
PCHQ32332-SZ-FCOGE Operating Manual Download Page 9](http://html1.mh-extra.com/html/unipower/quick-set-powercassette-pchq32332-sz-fcoge/quick-set-powercassette-pchq32332-sz-fcoge_operating-manual_843386009.webp)
Page 8
PCHS/TPCHS SERIES Quick-Set PowerCassette®
INSTALLATION & OPERATING MANUAL
Manual No. tpchs-2
pchs-tpchs-man-rev2-1214.indd
8.0 FRONT PANEL DESCRIPTION
The front panel of the Quick-Set PowerCassette is shown in Figure 3. On the left bottom of the
panel is the Input Power Good LED (green) and on the right bottom is the Output Power Good LED
(green). For the TPCHS and TPCHQS models there is a handle between the two LEDs. Also for
these models there is a mounting bracket on the right side of the front panel. This has a jackscrew
(Allen bolt) for securing the unit.
Figure 3 - Front Panel of the Quick-Set PowerCassette
9.0 MODULE SPECIFICATIONS
OUTPUT SPECIFICATIONS
Total Output Power, Continuous, Max .........................................600 Watts
Voltage Adjustment Range, Min ...........................................................±5%
Total Regulation
1
, V1, V2, V3 ..............................................................2.0%
Total Regulation
1
, V4, V5 .....................................................................3.0%
Ripple & Noise, Pk-Pk
2
............................................................1% or 50mV
Holdup Time ...................................................................................... 20mS
Dynamic Response
3
.........................................................................
300μS
Temperature Coefficient
.............................................................±0.02%/°C
Minimum Load, Any Output .....................................................................0A
Overload Protection ............................................................. Auto Recovery
Overvoltage Protection, V1, V2, V3 ...............................Latched Shutdown
Remote Sense, V1, V2, V3........................................Up to 0.25V Per Wire
Current Share, V1, V2, V3 ...................................... ±10% Full Load Rating
Standby Output........................................................................ +5V, 250mA
Output Power Good Signal .........................................................Logic High
Input Power Fail Signal...............................................................Logic High
Global Inhibit................................................................................Logic Low
Enable .........................................................................................Logic Low
Thermal Warning .........................................................................Logic Low
AC INPUT SPECIFICATIONS
Input Voltage Range ................................................................. 85-264VAC
Power Factor ........................................................................................0.99
Input Frequency............................................................................. 47-63Hz
Inrush Current Limiting ................................................................ 30A Peak
Input EMI Filter
6
..............................................................EN55022 Curve B
FCC20780 pt. 15J Curve B
Harmonic Distortion ............................................................... EN61000-3-2
Input Immunity, Conducted
Fast Transients, Line-Line ........................ ±2kV (EN61000-4-4 Level 3)
Surges, Line-Line ..................................... ±2kV (EN61000-4-5 Level 3)
Surges, Line-Ground ................................ ±4kV (EN61000-4-5 Level 4)
Input Protection ..............................................................Internal Fuse, 15A
DC INPUT SPECIFICATIONS
Input Voltage Range ...................................................................36-72VDC
Inrush Current Limiting ................................................................ 10A Peak
Input EMI Filter......................................................................Standard
Input Immunity, Conducted
Fast Transients, Line-Line ........................ ±2kV (EN61000-4-4 Level 3)
Surges, Line-Line ...................................±500V (EN61000-4-5 Level 1)
Surges, Line-Ground ..............................±500V (EN61000-4-5 Level 1)
Input Protection .........................................................Internal Fuse, 25A
GENERAL SPECIFICATIONS
Efficiency
4
.........................................................................75% at Full Load
Switching Frequency
PFC Converter (AC Input) ..........................................................48-110kHz
Output Converters ............................................................ 275kHz Nominal
Isolation, Class I, min.
5
Input-Output (AC Input/DC Input) ...........................3000VAC/1500VDC
Input-Ground (AC Input/DC Input) ..........................1500VAC/1500VDC
Output-Ground (AC Input/DC Input) ...............................50VDC/50VDC
MTBF (Bellcore .........................................200,000 HoursSafety Standards
EN60950, UL1950, CSA22.2 No.950
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature ...............................................0°C to 70°C Ambient
Derating .................................................................. 2.5%/°C, 50°C to 70°C
Storage Temperature .......................................................... -40°C to +85°C
Cooling .............................................................. Integral Ball Bearing Fans
PHYSICAL SPECIFICATIONS
Case Material ..............................................................................Aluminum
Dimensions, Inches(mm) .........................................1.6 H x 5.0 W x 11.0 D
(40.6 x 127 x 279)
Weight ...............................................................................3.3 lbs. (1.5 kg.)
NOTES:
1. No load to full load, including line regulation and load regulation.
2. Whichever is greater. 20MHz bandwidth. Measure with 0.1μFceramic
and 10μF tantalum capacitors in parallel across the output. For outputsof
2.5V or lower, the figure is 2% maximum.
3. <4% deviation recovering to within 1% for 25% load change.
4. Typical efficiency for 4 output unit with one high-current output of 5V
or lower. Efficiency can vary 5% or more depending on combination of
outputs.
5. Input-output isolation figure is for isolation components only. 100%
production Hipot tested.
6. When installed in compatible rack. Consult factory.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com