| 34
C64.65201 Issue 3
Jun 2019
Refitting the Door
Rehang the door onto the frame using the two part hinge pins ensuring the short
pins are fitted at the bottom of both hinges. Adjust the hinges on the mounting for
satisfactory door operation and to give approximately 1mm clearance between the
inner face of the door and the rolled edge on the frame. Tighten all hinge fasteners.
Then recheck the clearances and readjust if required.
Turn the door stay bracket assembly over and refit to the opposite side and attach
the bonding lead.
Ensure all of the fasteners disturbed are torque loaded to 1.5 Nm
The door is closed and secured using the locking bolt and bar and a standard
padlock.
Maintenance Activity
The signal design is such that it is maintenance free where the lens is subject to free
falling rain. However, Network Rail may mandate some maintenance activity and this
will be promulgated through the normal channels.
The LED module(s) can be tilted up and back using the hanging bracket and pivot
bar arrangement giving access from the rear of the signal ensuring the worker
remains in a position of safety.