During the set time periods, the mode will change automatically to the time period
setting. If a function key is pressed during the time period, the function key will change
to the new mode, after 15 seconds the system will revert back to the current time setting
mode.
i.e , if Period mode = Leaving mode, Function key -> Enter mode is pressed, after 15
seconds the mode will change back to Leaving mode.
The time periods should not be overlapped, but if they are overlapped, the application
order is Attend->Leave->Out->In->Access. If the time is set between 23:00~01:00, it
means from 23:00 to the 01:00 the following day.
▶
Blocking time: This function prevents the same user to authorize again in the set time.
There is no restriction if it is set 0, but if it is set larger than 0, the user can authorize
again when the set time (sec) is passed from the previous authorization. It can be set
up to 86,400 seconds (24 hours).
3.5.2. Function keys
The following window appears if you select the [Application] -> [Function key] in the
main menu.