5.8.2 Vibration
absorber
A vibration absorber (Part-No. A 906 250 00 01) has to be installed
into the driveline if auxiliary power take-off N05 is used for applica-
tions other than H63 or H64. The absorber can be ordered at author-
ized Freightliner Unimog dealers.
Figure 5.4: PTO N05 with vibration absorber and hydraulic pump
Figure 5.5: Installation of a vibration absorber on N05
Figure 5.6: Use of the N05 with a vibration absorber
Note for installation of the vibration absorber:
Refer to Figure 5.7 drawing of absorber.
The left side represented on the cut in the drawing must be bolted
with the device-sided consumer (e.g. hydraulic pump). The right side
(soft side) must be bolted with the prop shaft to the auxiliary power
take-off N05.
Observe installation directives
Warning:
Risk of damage to the vibration absorber!
Maximum thread engagement 0.59 in / 15 mm.