Body and Implement Mounting Guidelines U500 North America
Implement / Body Installation
August 2005
Page 105 of
294
4.14.2.1 Spreaders on the platform
General note: In case of a crash the spreader mounting
must
not
fail!
n
Prohibited mounting methods
It is not permitted to brace the implement (grit spreader) against the
sidewalls of the body. For this reason, the implement should not be
equipped with bracing devices.
•
It is not allowed to use the serial platform towing eyes.
•
It is not allowed to reinforce the implement by using the plat-
form’s sidewall.
Figure 4.49: Prohibited mounting
o
Stipulated mounting method
How to prevent the implement from sliding to the front
The implement must be secured against sliding to the front using two
mechanical stops (a and b). One of them has to be adjustable in
length. The implement fastening must be dimensioned in such a
way, that, even in case of an accident, it does not slide to the front.
a) Implement support at the rear edge of the floor or at the
cross beam of the subframe (preferred) (see Figure 4.51).
b) Adjustable stop at the front of the body (see Figure 4.50).
Figure 4.50: Rear mechanical locking
Figure 4.51: Front mechanical locking
Implement
Body
side
panel
Section A-A
Not per-
mitted!
A-A
ENKL
Rear view
Side view
ENKL
Stops at the rear edge of the floor
plate combined width must be at
least 32 in / 80 cm.
b
a
Bolts must not
be exposed to
shear load!
ENKL
ENKL
Side view
Top view
ENKLE
At least 40 in /
100 cm wide
Length
adjustable