3. Driving depth will be increased or decreased by rotating the depth of the drive knob or adjuster (Fig. 19A).
Test fire a fastener and check the depth. If the nail is driven in too deeply, rotate the adjuster clockwise to
make the safety bracket push downwards. Whereas, rotate the adjuster counter clockwise to make the
safety bracket push upwards. Repeat this step to achieve the desired results (See Fig. 20).
Clearing a Jammed Fastener
1.
CAUTION
: Disconnect the tool from the air supply.
2. Open the latch, rotate the lower housing and remove the nails of the lower housing.
3. Use a slender, soft steel rod to drive the drive blade to its uppermost position. Use the needle nose pliers to
remove the jammed fastener (Fig. 21).
4. Follow the instructions in