Preparing the Tool
1. After reading and understanding this entire manual, connect the tool to the air supply.
CAUTION
:
−
Keep the tool pointed away from yourself and others at all times.
−
Always connect the tool to an air supply before loading fasteners.
−
Do not load fasteners with the trigger or safety depressed.
−
Always wear Z87 approved safety glasses and hearing protection when preparing or operating the tool.
−
Never use a tool that leaks air or needs repair.
2. Depress the Handle (See A, Fig. 14) and open the Latch. Rotate the Upper Nail Housing to the side of the
Body.
3. The Adjuster Plate can be moved up and down when twisting the Adjuster Nut (see B, Fig.15). Depending
on the length of the nails, the Adjuster Plate should be adjusted correctly to the position indicated inside the
Lower Nail Housing.
4. Place a coil of nails over the Lower Nail Housing. Uncoil enough nails to reach the Feed Hook and place the
second nail between the teeth on the Feed Hook (see Fig. 16).
5. Close the Upper Nail Housing and depress the Latch (see Fig. 17).
6. Adjust the directional EXHAUST deflector (see Fig. 18), so that the exhaust air blast will be directed away
from the operator. Grasp the deflector and rotate it to the desired position for the current application.