5-4.Verify Operation
Before using tester, (1) Make sure the green LED is glowing, (2) Check tester on a known
live AC voltage that is within the defined detection range of the tester.
5-5.High Voltage Mode (100 to 1000V AC)
•
Place the tip of the tester near an AC voltage.
•
If the tester detects voltage within the defined detection range, the green LED will turn
off, the red LED will turn on, the beeper will beep rapidly.
5-6.Phase Sequence Test Mode
•
Place the tip of the tester close to the L1 phase wire, the tester will beep once, the
green and yellow LED flash rapidly alternately to indicate that the measurement of the
first phase sequence is complete.
•
Move the tip of the tester close to the L2 phase wire, when the measurement is
complete there will be two results:
1.The tester beep and green LED on about 5 seconds to indicate that is Correct phase
conformity (L2 is ahead of L1 120 degrees).
2.The tester beep and yellow LED on about 5 seconds to indicate that is Incorrect phase
conformity (L2 is lag of L1 120 degrees).
•
Test L1 and L3, L2 and L3 in the same way
Note:
To improve test accuracy, do not place the tester tip in the middle of the two phase
lines
Note:
If the phase sequence test is not completed within 1 minute, the red LED is
constantly on, the green and yellow LED flash alternately, and the tester will beep 5 times
to indicate that phase sequence test is wrong, and the test will reset the phase sequence
test mode, it need to measurement L1 again
5-7.Low Battery Indication
•
Replace the batteries if the mode indication LED does not turn on.
•
When the tester is on and the batteries are too low for reliable operation, the tester will
beep three times and the mode indication LED turn off indicating the tester is not
operational.
•
Replace the batteries to restore operation
5-8.Auto Power Off
•To conserve battery life, the tester will automatically turn off after approximately 5
minutes of inactivity.
•When powering down, the tester will beep twice and the mode indication LED wil
l turn
off.
5-9.Flashlight
•
Momentarily press the Flashlight button to turn the flashlight on or off.
•
To conserve battery life, the flashlight will automatically turn off after approximately 5
minutes when the NCV function is off.
•
The tester will beep twice as the flashlight auto power off
6.
Changing Batteries
1. .Carefully unscrew battery cap at the rear(flashlight end)of the tester.
2.Replace batteries with two AAA 1.5V batteries. Observe polarity.
3.Carefully align cover with tester as shown below.
4.Screw cover onto tester until it feels tight. Do not use excessive force.
5.Verify operation by using the tester on a known live AC voltage within the defined
detection range of the tester.
NOTE:
When batteries are loaded for the first time, please remove the white, rectangular
security strip before installing batteries.
NOTE:
When replacing the batteries,be sure to secure the cap firmly to maintain IP67
water and dust protection. A loose or overtightened battery cap may compromise water
and dust protection.
End of the Tester
Cap with springs to align
Observe correct polarity
when installing batteries
Push IN and Rotate Cap
back onto Tester Body
http://www.uniks.it
Via Vittori 57 48018 Faenza (RA) Italy
Tel. +39 0546.623002
Fax. +39 0546.623691