PART II: INSTALLATION
21
BURNER SAFETY
The burners - and the configurations described below - comply with the regulations in force regarding health, safety and the environ-
ment. For more in-depth information, refer to the declarations of conformity that are an integral part of this Manual.
Residual risks deriving from misuse and prohibitions
The burner has been built in order to make its operation safe; there are, however, residual risks.
DANGER! The safety elements and devices have been realized to protect from risks deriving from expected use,
adjustment and maintenance. Tampering with them, even minimally, and therefore creating dangerous situations
for people, property and the surrounding environment, is strictly forbidden.
Do not touch any mechanical moving parts with your hands or any other part of your body. Injury hazard
Do not touch any parts containing fuel (i.e. tank and pipes). Scalding hazard
Do not use the burner in situations other than the ones provided for in the data plate.
Do not use fuels other than the ones stated.
Do not use the burner in potentially explosive environments.
Do not remove or by-pass any machine safety devices.
Do not remove any protection devices or open the burner or any other component while the burner is running.
Do not disconnect any part of the burner or its components while the burner is running.
Untrained staff must not modify any linkages.
After any maintenance, it is important to restore the protection devices before restarting the machine.
All safety devices must be kept in perfect working order.
Personnel authorized to maintain the machine must always be provided with suitable protections.
ATTENTION: while running, the parts of the burner near the generator (coupling flange) are subject to overhea-
ting. Where necessary, avoid any contact risks by wearing suitable PPE.
Summary of Contents for RX63
Page 41: ......
Page 42: ......
Page 43: ......
Page 45: ...Service manual AZL2x LMV2x 3x Burner Management System M12916CD Rev 3 3 01 2017...
Page 52: ...8 Parameters level heating engineer...
Page 94: ...50 ERROR CODE TABLE...
Page 95: ...51...
Page 96: ...52...
Page 97: ...53...
Page 98: ...54...
Page 99: ...55...
Page 100: ...56...
Page 101: ...57...
Page 102: ...58...
Page 103: ...59...
Page 104: ...60...
Page 105: ...61...
Page 106: ...62...
Page 107: ...63...
Page 108: ...64...
Page 113: ......
Page 114: ......
Page 115: ......
Page 117: ...IG FU B...
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......