PART I: SPECIFICATIONS
6
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Technical Specifications
Type
RX1030.1
Model
M-.
MD. S.
*.
Y
.
x
.
xx
.
ES.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
1
BURNER TYPE
RX1025.1, RX1030R, RX1030.1
2
FUEL
M - Natural gas, L - LPG
3
OPERATION (Available versions)
MD - Fully modulating
4
BLAST TUBE
S - Standard,
LR = Extended blast tube + ABS polymer (silenced) air intake
SR = Standard blast tube + ABS polymer (silenced) air intake
5
DESTINATION COUNTRY
* - see data plate
6
BURNER VERSION
A - Standard
Y - Special
7
EQUIPMENT
1 = 2 gas gas proving system
8 = 2 gas gas proving maximum gas pressure switch
8
GAS CONNECTION
65 = DN65
80 = DN80
1000 = DN100
125 = DN125
9
MICRO-PROCESSOR CONTROL
ES = with no O
2
trim control, with no VSD control
EO = with O
2
trim control, with no VSD control
EI = with no O
2
trim control, with VSD control
EK = with O
2
trim control, with VSD control
RX1025.1
RX1030R
RX1030.1
Output
min - max kW
1500 - 8800
1300 - 9250
1550 - 10600
Fuel
M - Natural gas
Gas category
(see next paragraph)
Gas rate
M-
min.-max. (Stm
3
/h)
159 - 931
138 - 979
164 - 1122
Gas rate
LPG
min.- max. (Stm
3
/h)
56 - 328
49 - 345
58 - 396
Power supply
400V 3N~ 50
400V 3N~ 50
400V 3N~ 50
Total power consumption
kW
19,0
22,5
30,5
Fan motor power consumption
kW
18,5
22,0
30,0
Protection
IP40
Operation
Progressive - Fully modulating
Gas train 65
ØValves Connection
2”1/2 / DN65
2”1/2 / DN65
2”1/2 / DN65
Gas train 80
ØValves Connection
3” / DN80
3” / DN80
3” / DN80
Gas train 100
ØValves Connection
4” / DN100
4” / DN100
4” / DN100
Gas train 125
ØValves Connection
-
-
-
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service
Continuous
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(net calorific value H
i
= 34.02 MJ/Stm
3
); for L.P.G. (net calorific value H
i
= 93.5 MJ/Stm
3
)
Note2:
Maximum gas pressure = 500mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80%
Summary of Contents for RX1025.1
Page 41: ......
Page 42: ......
Page 43: ......
Page 45: ...User manual Siemens LMV 5x M12914CA Rev 0 03 2008...
Page 46: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 62: ...Annex1 Example for motor cable...
Page 63: ......
Page 64: ...Annex 2 Example for sensor cable...
Page 65: ......
Page 66: ......
Page 70: ......