Diagnosis and Maintenance
c07.fm
Checking the Base Stations and the Radio Coverage
A31003-C1020-S100-03-7620, 12/2017
84
OpenScape Cordless IP V2, Service Documentation
7.1.1 Base Stations
The purpose of this test is to check the functions of all base stations.
•
Take the mobile telephone to each of the base stations.
•
Holding the mobile telephone directly below, beside or above each base
station, turn it off and on again.
–
Display data, for example:
•
Set the mobile telephone to measuring mode.
NOTE:
Values recorded with a mobile telephone are not very precise and are
intended to provide a rough assessment only. In addition, different values may be
recorded on each mobile telephone even though the ambient conditions are
identical. If you require more accurate results, we recommended that you use the
Service tool (HCS-DECT).
Check:
–
RSSI value
(field strength value)
–
RPN value
(base station number)
Does the mobile telephone pick up the connection (synchronization) with
the base station to be tested?
–
FRAQ value
(transmission quality %)
Synchronization
between mobile
telephone and base
station
Radio connection to the
base station is displayed
on the screen as "Base n",
for example.
No synchronization
between mobile
telephone and base
station
"Base n" flashes, it means
that the radio connection
to the base station has
been lost.
Service
e
z
Base n
Ð
©
Service
e
z
Base n
Ð
©