MGC DIP SWITCH CONTROL FOR
The Uniden Uniden U4 DB-CP and the U65 DB-CP allow you to manually attenuate
the db gain of the device in increments of 5 and 10 db with a maximum of 15 db.
On the back panel of the device you will see one set of eight dip switches broken
down in two sections labeled ‘1900’ and ‘850’. (See image below)
HERE IS A BREAKDOWN OF THE DIP SWITCH
SECTIONS
The first section is labeled ‘1900 MHz’
The first two dip switches control the downlink of the 1900 MHz frequency. Dip switch
one represents a 10 db reduction and dip switch two represents a 5 db reduction. The
same applies to the next two dip switches which control the uplink of the 1900 MHz
frequency.
The second section is labeled ‘850 MHz’
The first two dip switches control the downlink of the 850 MHz frequency. Dip switch
one represents a 10 db reduction and dip switch two represents a 5 db reduction. The
same applies to the next two dip switches which control the uplink of the 850 MHz
frequency.
The Uniden Uniden U4 DB-CP and the U65 DB-CP can be reduced by 5, 10, or 15
db. When a dip switch is moved up to the on position it will implement a reduction for
the amount of gain indicated. Therefore, to implement a 5 db reduction, push the dip
switch marked 5 up. To implement a 10 db reduction push the dip switch marked 10
up. To implement a 15 db reduction push both dip switches marked 5 and 10 up.
25
Uniden U4 Uniden U65 DB-CP MGC dip switches
&