background image

 

REPAIR KIT INSTRUCTIONS

 

 

Roseville, MN 

 

Ph: 1-800-444-2373 

Fax: 651-645-7390 

www.fastestinc.com 

 

 

WP161, Rev A   4/2/2019                 

Mounting U-Clamp 

Oil Cup 

1/8”  NPT  

HYDRAULIC 

“OUTLET” PRESSURE  

PORT 

1/4”  NPT AIR 

“INLET” PRESSURE  

PORT 

 

Connector Maintenance: 

 

A daily, weekly and periodic inspection of the booster and connectors by competent person 
is recommended. User must establish a regular interval for maintenance as determined by 
the user media and operational environment. 

 

Inspection should include visual checks of the ports, hoses, hydraulic oil level, wear, dirt 
accumulation and damage. 

 

Use only original 

FasTest

 

spare parts that are designed for the application and are subject 

to strict quality control. See Warranty. 

 

Safety Warnings – Guidelines: 

 

If instructions are not completely understood by operator or components are missing, 
contact 

FasTest

 

before attempting use of the booster. 

 

FasTest Pilot Booster & FE

 

Connectors 

 must only be used with test pieces of a specific 

size as indicated by the part number. Improper use could cause separation of the connector 
from the test piece resulting in physical harm or damage. 

FasTest, Inc. Product Warranty

 

FasTest, Inc. warrants its products against defects of workmanship and/or material for 1 year from the date of the sale by FasTest, Inc.  
This  warranty  is  void  if  the  product  is  misused,  tampered  with  or  used  in  a  manner  that  is  not  in  accordance  with  FasTest,  Inc. 
recommendations and/or instructions. FasTest, Inc. is not liable for consequential or other damages including, but not limited to, loss, 
damage,  personal  injury,  or  any  other  expense  directly  or  indirectly  arising  from  the  use  of  or  inability  to  use  its  products  either 
separately  or  in  combination  with  other  products.  ALL  OTHER  WARRANTIES  EXPRESSED  OR  IMPLIED,  WHETHER  ORAL  OR 
WRITTEN,  INCLUDING  BUT  NOT  LIMITED  TO  WARRANTIES  OR  MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR 
PURPOSE ARE EXPRESSLY EXCLUDED. 
Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original selling price, at 
the option on FasTest, Inc.  All allegedly defective products must be returned prepaid transportation to FasTest, Inc. along with 
information describing the products performance, unless disposition in the field is authorized in writing by FasTest, Inc. 

 
 
 
 
 
 
 
 
 
 

PB-1015 Pilot Pressure Booster Repair 
Kit Instructions 

Description: 

The PB-1015 Pressure Booster is a compact 

pressure intensifier which uses compressed air to provide up to 
600 psi hydraulic pressure. Designed to be used with a FasTest 
FE Connector and Urethane Seal Set for sealing on external 
threads and irregular surfaces. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
Please thoroughly read and understand these repair instructions 
prior to operating the Pilot Booster. For reference see WP016 
for 

Pilot Booster

 Operating/Installation Instructions. 

 

 

Dis-assembly Instructions 

 

Re-assembly Instructions 

 

Safety Warnings – Guidelines 

Reviews: